Document No. 540-219
Rev. 2, January, 1999
Room Pressurization Controller – Pneumatic
Output
P
PP
Pa
aa
age
ge ge
ge 1
11
1
o
oo
of
f f
f 8
88
8
P
PP
Pr
rr
rodu
oduodu
oduc
cc
ct
t t
t D
DD
De
ee
es
ss
sc
cc
cr
rr
ri
ii
ip
pp
pt
tt
ti
ii
ion
onon
on
These instructions explain how to field install (pages 1
through 3) or replace (pages 3 through 4) a Room
Pressurization Controller – Pneumatic Output with or
without Autozero Modules.
P
PP
Pr
rr
rodu
oduodu
oduc
cc
ct
t t
t N
NN
Nu
uu
um
mm
mbe
bebe
ber
rr
r
540-716 Room Pressurization Controller –
Pneumatic Output
540-717 Room Pressurization Controller –
Pneumatic Output with Autozero
Modules
Shipping carton includes a pre-assembled metal
enclosure with controller board and cover, pneumatic
output modules, Autozero Modules with brackets
(optional), and four self-tapping/drilling screws.
I
II
In
nn
ns
ss
st
tt
ta
aa
all
llll
lla
aa
at
tt
ti
ii
ion
on on
on C
CC
Con
onon
onv
vv
ven
enen
ent
tt
ti
ii
ion
onon
ons
ss
s
C
CC
CA
AA
AU
UU
UT
TT
TI
II
IO
OO
ON
NN
N:
::
:
Equipment damage or loss
of data may occur if the user
does not follow procedure
as specified.
R
RR
Requ
equequ
equi
ii
ir
rr
red
ed ed
ed T
TT
Too
oooo
ools
lsls
ls
Electro-Static Discharge (ESD) wrist strap
Small flat-blade screwdriver
Medium flat-blade screwdriver
Medium-duty electric drill
1/4 in. (6.35 mm) hex nut bit
Portable Operator’s Terminal with Controller
Interface Software Rev. 2.0 or higher (required
for controller replacement only)
Additional tools needed if not using self-tapping
option:
1/4 in. (6.35 mm) hex nut driver
1/8 in. (3 mm) bit
P
PP
Pr
rr
re
ee
er
rr
requ
equequ
equisi
isiisi
isit
tt
te
ee
es
ss
s
Room temperature sensor installed (optional)
Air velocity sensors installed in ducts
A source of 24 Vac Class 2 power available
Supply power to the unit is OFF
An air supply line is available at the controller
E
EE
Ex
xx
xpe
pepe
pec
cc
ct
tt
ted
ed ed
ed I
II
In
nn
ns
ss
st
tt
ta
aa
all
llll
lla
aa
at
tt
ti
ii
ion
on on
on T
TT
Ti
ii
im
mm
me
ee
e
New controller installation 10 Minutes
Replacement (old controller has
removable terminal blocks)
6 Minutes
Replacement (old controller
does not have removable
terminal blocks)
16 Minutes
N
NN
NO
OO
OT
TT
TE
EE
E:
::
: You may require additional time for database
work at the field panel.
N
NN
Ne
ee
ew
w w
w I
II
In
nn
ns
ss
st
tt
ta
aa
all
llll
lla
aa
at
tt
ti
ii
ion
on on
on I
II
In
nn
ns
ss
str
trtr
tru
uu
uc
cc
ct
tt
ti
ii
ion
onon
ons
ss
s
N
NN
NO
OO
OT
TT
TE
EE
E:
::
: These steps only refer to new installations.
For replacement instructions, refer to pages 3-4. For
Autozero Module installation, refer to instruction 540-
199.
The following tasks can be performed by the
electrician:
1. Loosen, but do not remove, the cover screws and
remove the enclosure cover. Using the rear panel
of the enclosure as a template (Figures 1 and 2),
mark the location for the four screw holes where
you will install the enclosure.
2. Do one
oneone
one of the following:
I
II
If
f f
f u
uu
us
ss
si
ii
ing
ng ng
ng t
tt
the
he he
he s
ss
se
ee
el
ll
lf
ff
f-
--
-t
tt
ta
aa
app
pppp
ppi
ii
ing
ng ng
ng s
ss
sc
cc
cr
rr
re
ee
ew
ww
ws
ss
s:
::
: Using the
drill and the hex nut bit, start the screws.
(Screws do not require starter holes.)
I
II
If
f f
f no
nono
not
tt
t
u
uu
us
ss
si
ii
ing
ng ng
ng t
tt
the
he he
he s
ss
se
ee
el
ll
lf
ff
f-
--
-t
tt
ta
aa
app
pppp
ppi
ii
ing
ng ng
ng s
ss
sc
cc
cr
rr
re
ee
ew
ww
ws
ss
s:
::
: Drill four
1/8 in. (3 mm) pilot holes for the screws.
Using the hex nut driver, start the screws.

Summary of content (8 pages)