The Operator Display Panel supports the following
functions:
l Digital display of face velocity in fpm (MPS)
l Green, yellow and red status lights
l Emergency purge push button
l Alarm horn with silence push button
l Auxiliary push buttons for more information
l Animated Graphics to encourage users to close
sashes when not using the hood
The face velocity display also indicates high and low
alarm conditions, emergency purge activation, and
diagnostic failure mode conditions when the controller
is in the minimum flow mode. Face velocity fpm
(MPS) display may be blanked as an option for
applications where the user does not desire the face
velocity reading.
Operator Display Panel
Specifications
Face Velocity Display
Range
0 fpm to 255 fpm
(0.0 MPS to 1.3 MPS)
Display Resolution 1 fpm adjustable up to 255 fpm
Push-Buttons Switch
inputs
1 Emergency Purge
1 Horn Silence
2 Momentary Auxiliary
Alarm Horn 85 dB @ 4" (10 cm)
Dimensions
5.5" H × 3.125" W × 1.5" D
(140 mm × 80 mm × 39 mm)
Weight 8 oz. (0.2 kg)
Product Ordering
Description Product Part
Number
BACnet Fume Hood Controller 570-00701PA
BACnet Lab Controller Module 570-8xxPA
BACnet Fume Hood Controller (smoke listed) 570-00701PKA
Sash Open Area Module DXA.S12C
Off-board Air Module 550-819B
Description Product Part
Number
Operator Display Panel 575-820A
Power Module (for ODP) AQM2200
UniTrak Sash Sensors 149-269
Room Sensor Cable 25 ft.
Room Sensor Cable 50 ft.
588-100A
588-100B
Retracting Cable Sash Sensor
50 in range
80 in range
546-04000
546-04001
Exhaust Terminal LGEn….n
Venturi Air Valve – Constant Volume – Variable
Volume – Zero Leakage Shut-Off AVCn….n
AVVn….n
AVZn….n
Venturi Air Valve Accessories AVAn….n
Laboratory Electronic Actuator GNP191.1P
Document Information
Description Product Part
Number
BACnet Protocol Implementation Conformance
(PIC) Statement
149-1033
BACnet Lab Controller Module 149-855
Operator Display Panel II 149-1029
Conical Venturi Air Valve for Critical
Environments
149-524
Venturi Air Valve Accessories 149-495
Laboratory Exhaust Air Terminal 149-320
Laboratory Electronic Actuator Submittal Sheet 155-771
Fume Hood Sash Open Area Module (SOAM)
Installation Instructions
A6V10801244
Sash Open Area Module (SOAM) Technical
Specification Sheet
A6V10801251
Retracting Cable Sash Sensor 570-112
UniTrak Sensor Assembly Kit 546-00449