Extractor hood siemens-home.
en Table of contents INSTRUCTION MANUAL.......................................................... 2 sno i t cur t sen I rof 8 Intended use................................................................... 2 ( Important safety information ........................................ 2 7 Environmental protection ............................................. 4 Ç Operating modes ........................................................... 4 1 Operating the appliance..............................................
Important safety information en : Warning Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coaloperated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney).
en Environmental protection : Warning Risk of electric shock! ■ A defective appliance may cause electric shock. Never switch on a defective appliance. Unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service. Risk of electric shock!are dangerous. Repairs ■ Incorrect repairs may only be carried out and damaged power cables replaced by one of our trained after-sales technicians.
Operating the appliance 1Operating the appliance These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance. ecna i l p a eh t gn i t arepO en Note: Switch on the extractor hood when you start cooking and switch it off again several minutes after you have finished cooking. This is the most effective way of removing the kitchen fumes.
Operating the appliance en Control panel model 2 DXWR Explanation Fan on/off # = & ! Light on/off/dimming Boost function (short-term maximum power) Automatic mode with fan run-on -|||+ Range of fan settings Setting the fan Switching on ■ ■ Touch the # symbol. The fan starts at setting ƒ. Slide your finger across the III settings range to change the fan speed. Switching off Touch the # symbol.
Cleaning and maintenance Saturation display When the metal grease filters or the activated charcoal filter are/is saturated, an audible signal sounds for approximately four seconds after the fan is switched off. In addition, the corresponding symbol appears on the display: ■ ■ Metal grease filter:! Activated charcoal filter: " If you have not yet done so, the metal grease filters should be cleaned or the activated charcoal filter changed.
en Cleaning and maintenance Cleaning the metal mesh grease filters Removing metal grease filter These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance. 1. Open the lock and fold down the metal grease filter. : Warning While doing this, place the other hand under the metal grease filter. 2. Take the metal grease filter out of the holder. Risk of fire! Grease deposits in the grease filter may catch fire.
Trouble shooting 3Trouble shooting Malfunctions often have simple explanations. Please read the following notes before calling the after-sales service. gn i t o h s e l buo r T : Warning Risk of electric shock! Incorrect repairs are dangerous. Repairs may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.
en Customer service 4Customer service Basic equipment: Starter set for circulating-air mode wide When calling us, please give the product number (E no.) and the production number (FD no.) so that we can provide you with the correct advice. The rating plate with these numbers can be found inside the appliance (remove the metal mesh grease filter to gain access).
Important safety information en INSTALLATION INSTRUCTIONS (Important safety information Installation instructions PLQ PP PD[ PP PLQ PP PP PLQ PP ! PP ! PP Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners.
en Important safety information Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coaloperated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney).
General information KGeneral information Checking the wall ■ Exhaust air mode no i t amro f n i l areneG ■ : Warning Risk of death! Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances.
en Installation 5Installation Preparing the installation no i t a l a t s n I Caution! Ensure that there are no electric wires, gas or water pipes in the area where holes are to be made. Installation 1. Screw on the fixing bracket for the flue duct. ¨ $ 1. Mark a vertical centre line on the wall from the ceiling to the lower edge of the extractor hood. 2. Mark positions for the screws and the contour of the attachment area. 3.
Installation Attaching and aligning the appliance Connecting the pipes 1. First, remove the protective foil from the back of the Note: If using an aluminium pipe, smooth the connection area beforehand. appliance and, following installation, remove the foil completely. 2. When attaching the appliance, ensure that it engages firmly with the brackets. « 3. Align the appliance horizontally by turning the brackets. If required, the appliance can be moved to the right or left.
BSH Hausgeräte GmbH Carl-Wery-Straße 34, 81739 München, GERMANY siemens-home.