>HQ@ ,QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH ([WUDFWRU KRRG
Ú Table of contents e[nuoIrs]acitlfde INSTRUCTION MANUAL............................................................ 2 Important safety information................................................ 2 Environmental protection ..................................................... 4 Environmental protection..............................................................4 Operating modes................................................................... 4 Exhaust air mode .........................................
Danger of suffocation! Packaging material is dangerous to children. Never allow children to play with packaging material. Danger of death! Risk of poisoning from flue gases that are drawn back in. Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as room air-dependent heat-producing appliance is being operated. In any case, consult your responsible Master Chimney Sweep.
Items placed on the appliance may fall down. Do not place any objects on the appliance. ■ The light emitted by LED lights is very dazzling, and can damage the eyes (risk group 1). Do not look directly into the switched on LED lights for longer than 100 seconds. Risk of electric shock! ■ A defective appliance may cause electric shock. Never switch on a defective appliance. Unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.
Operation These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance. Note: Switch on the extractor hood when you start cooking and switch it off again several minutes after you have finished cooking. This is the most effective way of removing the kitchen fumes. Control panel model 1 Control panel If you have not yet done so, the metal mesh grease filters should be cleaned or the activated carbon filter changed now.
Boost function The boost function is a short-term maximum power setting which can be activated in any fan setting. Control panel model 3 Control panel Press the & button. After approx. 20 seconds, the fan switches back to the previously set fan setting. Fan run-on time Press the x button. The fan continues to operate for a further 10 minutes, and switches off automatically after this time. If the lighting is switched on, it remains on.
If the sensor control responds too quickly or too slowly, it can be changed accordingly: If you have not yet done so, the metal mesh grease filters should be cleaned or the activated carbon filter changed now. 1. When the fan is switched off, press the ! button and hold it For instructions on how to clean the metal mesh grease filters, please refer to the section Cleaning and maintenance. 2.
Cleaning the metal mesh grease filters Removing metal mesh grease filter : Risk of fire! 1. Open the lock and fold down the metal grease filter. While Grease deposits in the grease filter may catch fire. Clean the grease filter at least every 2 months. Never operate the appliance without the grease filter. 2. Take the metal grease filter out of the holder. doing this, place the other hand under the metal grease filter. Notes ■ Do not use any aggressive, acidic or alkaline cleaning agents.
Replacing bulbs : Risk of electric shock! When changing the bulbs, the bulb socket contacts are live. Before changing the bulb, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Important Only use a bulb of the same type and same power (see the bulb holder or rating plate inside the appliance) – to do this, remove the metal mesh grease filter. Replacing halogen bulbs Note: When inserting halogen bulbs, do not touch the glass tube.
Accessories for circulating-air mode (not included in the delivery) Notes ■ Follow the installation instructions supplied with the accessories. ■ Basic equipment: CleanAir recirculation module - wide 7 For appliances with an additional internal filter, only the CleanAir recirculation module can be used.
INSTALLATION INSTRUCTIONS Installation instructions PLQ PP PD[ PP [ PLQ PP [ PP PLQ PP [ [ [ [ [ [ [ ■ ■ ! PP ■ This appliance is installed on the wall. Follow the enclosed installation instructions for additional special accessories (e.g. for circulating-air mode). The surfaces of the appliance are sensitive. Avoid damaging them during installation. ! PP : Important safety information Read these instructions carefully.
Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coaloperated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney). In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied.
General information Exhaust air mode : Risk of death! Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust air is to be conveyed into a non-functioning smoke or exhaust gas flue, you must obtain the consent of the heating engineer responsible. ■ Flat ducts should have no sharp deflections.
Installation Attaching and aligning the appliance 1. Screw on the fixing bracket for the flue duct. ¨ 1. Initially remove the protective foil from the back of the $ appliance and, following installation, remove the foil completely. 2. When attaching the appliance, ensure that it engages firmly with the brackets. « 3. Align the appliance horizontally by turning the brackets. If required, the appliance can be moved to the right or left. ¬ [ ' ( 2.
Removing the safety caps If the safety caps must be removed, use a flat screwdriver. Attaching the flue duct : Risk of injury! From sharp edges during installation. Always wear protective gloves while installing the appliance. 1. Separate the flue ducts. To do this, remove the adhesive tape. 2. Remove the protective foil from both flue ducts. 3. Push one flue duct into the other.
Siemens-Electrogeräte GmbH Carl-Wery-Straße 34 81739 München Germany *9000852563* 9000852563 930703