Operating Instructions
Table Of Contents
- SITRANS LR250 with mA/HART
- Legal information - Warning notice system
- Table of contents
- 1 Introduction
- 2 Safety information
- 3 Description
- 4 Installing/mounting
- 5 Connecting
- 6 Commissioning
- 7 Remote operation
- 7.1 Operating via SIMATIC PDM
- 7.1.1 Functions in SIMATIC PDM
- 7.1.2 Initial setup
- 7.1.3 Updating the Electronic Device Description (EDD)
- 7.1.4 Quick Start Wizard via SIMATIC PDM
- 7.1.5 Changing parameter settings using SIMATIC PDM
- 7.1.6 Parameters accessed via pull-down menus
- 7.1.6.1 Echo profile utilities
- 7.1.6.2 Echo profile
- 7.1.6.3 View saved echo profiles
- 7.1.6.4 TVT Shaper
- 7.1.6.5 Auto false echo suppression
- 7.1.6.6 Echo setup
- 7.1.6.7 Maintenance
- 7.1.6.8 Select analog output
- 7.1.6.9 Self test
- 7.1.6.10 Loop test
- 7.1.6.11 Configuration flag reset
- 7.1.6.12 Master reset
- 7.1.6.13 Wear
- 7.1.6.14 HART Communication
- 7.1.6.15 Process variables
- 7.1.6.16 Trend
- 7.1.6.17 Device status
- 7.1.6.18 Update
- 7.1.6.19 Security
- 7.2 Operating via AMS Device Manager
- 7.3 Operating via FDT (Field Device Tool)
- 7.1 Operating via SIMATIC PDM
- 8 Parameter reference
- 9 Service and maintenance
- 10 Diagnosing and troubleshooting
- 11 Technical data
- 12 Dimension drawings
- 12.1 Universal polymeric flange
- 12.2 Aluminum horn antenna
- 12.3 Mounting bracket
- 12.4 Aluminum horn with polypropylene lens antenna and polymeric flange
- 12.5 Stainless steel threaded horn antenna
- 12.6 Stainless steel threaded horn antenna with extension
- 12.7 Stainless steel flanged horn antenna
- 12.8 Stainless steel flanged horn antenna with extension
- 12.9 PTFE Flanged encapsulated antenna (2"/DN50/50A sizes only)
- 12.10 PTFE Flanged encapsulated antenna (3"/DN80/80A sizes and larger)
- 12.11 Hygienic encapsulated antenna (2" ISO 2852 sanitary clamp)
- 12.12 Hygienic encapsulated antenna (3" ISO 2852 sanitary clamp)
- 12.13 Hygienic encapsulated antenna (4" ISO 2852 sanitary clamp)
- 12.14 Hygienic encapsulated antenna (DN50 nozzle/slotted nut to DIN 11851)
- 12.15 Hygienic encapsulated antenna (DN80 nozzle/slotted nut to DIN 11851)
- 12.16 Hygienic encapsulated antenna (DN100 nozzle/slotted nut to DIN 11851)
- 12.17 Hygienic encapsulated antenna (DN50 aseptic slotted nut to DIN 11864-1)
- 12.18 Hygienic encapsulated antenna (DN80 aseptic slotted nut to DIN 11864-1)
- 12.19 Hygienic encapsulated antenna (DN100 aseptic slotted nut to DIN 11864-1)
- 12.20 Hygienic encapsulated antenna (DN50 aseptic flange to DIN 11864-2)
- 12.21 Hygienic encapsulated antenna (DN80 aseptic flange to DIN 11864-2)
- 12.22 Hygienic encapsulated antenna (DN100 aseptic flange to DIN 11864-2)
- 12.23 Hygienic encapsulated antenna (DN50 aseptic clamp to DIN 11864-3)
- 12.24 Hygienic encapsulated antenna (DN80 aseptic clamp to DIN 11864-3)
- 12.25 Hygienic encapsulated antenna (DN100 aseptic clamp to DIN 11864-3)
- 12.26 Hygienic encapsulated antenna (Tuchenhagen Type N)
- 12.27 Hygienic encapsulated antenna (Tuchenhagen Type F)
- 12.28 Threaded PVDF antenna
- 12.29 Threaded connection markings
- 12.30 Raised-Face flange
- 12.31 Raised-Face flange per EN 1092-1 for flanged encapsulated antenna
- 12.32 Flat-Face flange
- 12.33 Aseptic/hygienic flange DN50, DN80, DN100 for DIN 11864-2
- 12.34 Process connection tag (pressure rated versions)
- A Appendix A: Technical reference
- A.1 Principles of operation
- A.2 Echo Processing
- A.3 Analog Output
- A.4 Maximum Process Temperature Chart
- A.5 Process Pressure/Temperature derating curves
- A.5.1 Pressure Equipment Directive, PED, 14/68/EU
- A.5.2 Stainless steel horn antenna
- A.5.3 Stainless steel flanged horn antenna
- A.5.4 PTFE flanged encapsulated antenna
- A.5.5 Aluminum horn, with polypropylene lens antenna version with polypropylene flange
- A.5.6 PVDF antenna
- A.5.7 Hygienic encapsulated antenna
- A.6 Loop power
- A.7 Startup behavior
- B Appendix B: HART communications
- C Appendix C: Certificates and support
- 13 List of abbreviations
- 14 LCD menu structure
- Glossary
- Index
11.4 Mechanical
Transmitter
housing
Stainless steel
horn version
Process connec‐
tion
Flange 2, 3, 4" (ASME B16.5 raised face 150 lb, 300
lb) DN50, DN80, DN100, DN150 (EN 1092-1
TYPE B1 raised face PN10/16, PN25/40),
50A, 80A, 100A (10K JIS B 2220 flat faced)
Threaded 1.5" NPT (ASME B1.20.1), R (BSPT, EN
10226‑1), G (BSPP, EN ISO 228‑1), 2" NPT
(ASME B1.20.1), R (BSPT, EN 10226‑1), G
(BSPP, EN ISO 228‑1), 3" NPT (ASME
B1.20.1), R (BSPT, EN 10226‑1), G (BSPP,
EN ISO 228‑1)
Wetted materials 316L stainless steel with PTFE emitter option‐
al Alloy N06022/2.4602 (Hastelloy
®
C-22 or
equivalent) with PTFE emitter, FKM or FFKM
seal
Horn 1.5" (40 mm), 2" (50 mm), 3" (80 mm), and 4"
(100 mm) horn, optional 100 mm (4") horn ex‐
tension
Aluminum horn,
with polypropylene
lens antenna ver‐
sion
Process connec‐
tion
Flange Universal mount ANSI/DIN/JIS
3" (80 mm), 4" (100 mm), 6" (150 mm)
Wetted materials Polypropylene, FKM seal
Horn 3" (80 mm) polyester powder coated exterior
PTFE flanged En‐
capsulated
Process connec‐
tion
Flange 2, 3, 4, 6" (ASME 150 lb); DN50, DN80,
DN100, DN150 (PN10/16); 50A, 80A, 100A,
150A (JIS 10K)
Wetted materials TFM
TM
1600 PTFE lens
PTFE hygenic en‐
capsulated
Hygienic encapsulated antenna
(HEA) connection
ISO 2852 (2, 3, 4")DIN 11851 (DN50, DN80,
DN100)DIN 11864‑1/2/3 (DN50, DN80,
DN100)Tuchenhagen (Type F [50 mm] and
Type N [68 mm])316L /1.4404 or 316L /1.4435
stainless steel
Wetted materials 316L /1.4404 or 316L /1.4435 stainless steel
TFM
TM
1600 PTFE lens
EPDM or FKM available as accessories
PVDF threaded Thread sizes
2" NPT [(Taper), ASME B1.20.1], 2" [(BSPT),
EN 10226], 2" [(BSPP), EN ISO 228-1]
Wetted materials PVDF (Polyvinylidene fluoride)
Enclosure Construction aluminum, polyester powder-coated
Conduit entry 2 x M20x1.5, or 2 x ½" NPT
Ingress protection Type 4X, Type 6, IP67, IP68
Technical data
11.4 Mechanical
SITRANS LR250 with mA/HART