Operating Instructions

Table Of Contents
6.2.2.4 The LCD display
Measurement mode display
Normal operation
M
[ ]
LEVEL
21.40
C
DATA EXCH.
18.91
r
1 2 3 4
67 58
Toggle indicator
a)
for linear units or %
Selected operation: level, space, distance, or volume
Measured value (level, space, distance, or volume)
Units
Bar graph indicates level
Secondary region indicates on request
b)
electronics temperature, echo confidence, loop cur‐
rent, or distance
Text area displays status messages
Device status indicator, see Device status icons (Page 120)
a)
Press UP or DOWN arrow to switch.
b)
In response to a key press request. For details, see Handheld Programmer (Page 50) for key func‐
tions in Measurement mode.
Fault present
1
2
6/2(
Device status indicator, see Device status icons (Page 120)
Text area displays status messages
Commissioning
6.2 Local commissioning
SITRANS LR260 with mA/HART
48 Operating Instructions, 11/2019, A5E32337683-AD