Full Product Manual

2
METER
CENTERS
Meter
Combinations
Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog
2-41
MC0816B1200TH (shown)
MC0816B1XXX(R)TH
200A OH/UG feed, 8 circuit,
with feed thru lugs.
MC3042B1400SDL MC2442B1400SDBMC0816B1400RLTM
MC0816B1350RLTM
400A meter load center
combination, 30 space/
40 circuit lever bypass
400A bolt in K4 socket with
400A main
One factory installed main,
provisions for up to 200A field
installed main, 8 circuits, lever
bypass.
n UL listed
n 22,000 AIC Rated
n Pad locking provisions on all devices
n Side hinge doors removable by backing out only one screw
Catalog Number
Amp
Rating
(Cont.)
Utility
Incoming
Bypass
Type
No. of
Spaces
No. of
Circuits
Dimensions (inches)
Main
Breaker
Short
Circuit
Rating
Hub
Provision
5th
Jaw
Cover
Type
H W D
Meter-Load Center Combination, 150-200amp, Full Loadcenter Width
MC0816B1150TH
150
OH/UG None 8 16 21.0 22.9 5.0
QN2150RH
22,000 2-RX EMC5J
Ring
MC0816B1200TH
200 QN2200RH
MC0816B1150RTH
150 QN2150RH
Ringless
MC0816B1200RTH
200 QN2200RH
MC1224B1125
125
OH/UG None 12 24
16.0 22.89 5.0 Q2125H
22,000
RX EMC5J Ring
MC1224B1125R
125 32.0 14.0 5.0
EQ9575/
EQ9677
RX-top
HC-bot
EC5J2 Ringless
MC2040B1150
150
OH/UG None 20 40 18.0 22.9 5.0
QN2150RH
22,000 RX EMC5J
Ring
MC2040B1200
200 QN2200RH
MC2040B1150R
150 QN2150RH
Ringless
MC2040B1200R
200 QN2200RH
Meter-Load Center Combination, 350-400amp, Lever Bypass
MC0408B1400RLTM
320 OH/UG
HQ
Lever
4 8
29.0 27.0 6.0
QN2200H
22,000 HD H35815-2 Ringless
MC0816B1350RLTM
8 16 QN2150H
MC0816B1400RLTM
8 16 QN2200H
Meter-Load Center Combination, 400amp, Lever Bypass, Underground Feed Only
MC0816B1400SDL
320 UG
HQ
Lever
8 16 39.7 30.2 6.4
(1) QN &
Provisions for
(1)QN or (1)QP
22,000 HD H35815-2 Ringless
MC2442B1400SDL
24 42 39.5 30.3 6.0 JXD6
MC3042B1400SDL
30 42 39.7 30.2 6.4
(1) QN &
Provisions for
(1)QN or (1)QP
Meter-Load Center Combination, 400amp, K4 Bolt-In Meter Socket, Underground Feed Only
MC2442B1400SDB
400
UG
Bolt In
K4
No By-
pass
24 42
39.7 30.2 6.4
Factory JXD6
22,000 HD
Ringless
MC3042B1400SDB
30 42
Factory
QN2200RH
Field QP(H),
QNR(H)
n Suitable for use only as service entrance equipment
n Contact local utility to confirm meter socket approval prior
to installation
n See end of section for dimensions and wiring diagrams
Meter Mains
Side-By-Side
Meter Load Center Combinations
Side-By-Side
Over-Under
Over-Under Combo
EUSERC Meter Load Center Combinations
Side-By-Side Full Load Center
Side-By-Side 400A
Over-Under 14”
Side-By-Side 14”
EUSERC
EUSERC
EUSERC
EUSERC Meter Mains
Side-By-Side
Side-By-Side 400A
EUSERC
EUSERC
EUSERC
Feed thru lugs included.
Bolt-in meter socket. This device should not be confused with class
320amp lever bypass devices. Device can not be converted to lever
bypass. Installer should ensure device approval prior to installation.
Product Category RESI
Meter Centers
Surface Mount, Side-by-Side Meter-Load Center Combination, 1-Phase, 3-Wire 120/240V AC

Summary of content (1 pages)