Specifications

MC35i AT Command Set
8.3 AT+CREG
s
m
obil
e
MC35i_ATC_V01.03 Page 176 of 444 5/7/04
Confidential / Released
Command Description
Read command returns the URC presentation mode <n> and an integer <stat> that shows the registration sta-
tus of the ME. The location information elements
<lac> and <ci> are returned only when <n>=2 and ME is
registered to the network.
Use the write command to select the type of URC. Two types of URCs are available:
<n>=1: +CREG:<stat>
<n>
=2: +CREG:<stat>[,<lac>,<ci>]
Parameter Description
0
(&F)
disable URCs
1 enable URC +CREG:
<stat> to report status of network registration
2 enable URC +CREG:
<stat>[,<lac>,<ci>] to report status of network regis-
tration including location information. Please note that optional parameters will
not be displayed during call.
0 Not registered, ME is currently not searching for new operator
There is a technical problem. User intervention is required. Yet, emergency
calls can be made if any network is available. Probable causes.
No SIM-Card available
•No PIN entered
No valid Home PLMN-Entry found on the SIM
1 Registered to home network
2 Not registered, but ME is currently searching for a new operator.
The ME searches for an available network. Failure to log in until after more than
a minute may be due to one of the following causes:
No network available or insufficient Rx level.
The ME has no access rights to the networks available.
Networks from the SIM list of allowed networks are around, but login fails
due to one of the following reasons:
- #11 ... PLMN not allowed
- #12 ... Location area not allowed
- #13 ... Roaming not allowed in this location area
After this, the search will be resumed (if automatic network search is
enabled).
The Home PLMN or an allowed PLMN is available, but login is rejected by
the cell (reasons: Access Class or LAC).
If at least one network is available, emergency calls can be made.
3 Registration denied
If automatic network search is enabled:
Authentication or registration fails after Location Up-date Reject due to one
of the following causes:
- #2 ... IMSI unknown at HLR
- #3 ... Illegal MS
<n>
(num)(&W)(&V)
<stat>
(num)(&V)