Specifications

AT Command Set for L55 Platform 2003-11-21
Copyright Siemens AG 2003 All Rights Reserved Page 19 of 131
2.3.3.2 AT+CCFC
AT+CCFC Call forwarding
Test command
AT+CCFC=?
Response
+CCFC: (list of supported <reas>s)
OK/ERROR/+CME ERROR
Parameter
<reas>
0
1
2
3
4
5
Always
If busy
If no answer
If not available
All reasons (0-3)
All conditional reasons (1-3)
Write command
AT+CCFC=<reas>, <mode>[, <num>[,<type>[,<class>[,,,<time>]]]]
Parameter
<reas>
See Test command
<mode>
1
2
3
4
5
Deactivate
Activate
Query
Install
Delete
<num> Telephone number
<type> Type of telephone number
<class>
1
2
4
7
8
16
32
64
128
X
Voice
Data
Fax
Voice, Data and FAX (default)
SMS
data circuit sync
data circuit async
dedicated packet access
dedicated PAD access
combination of some of the above classes, e.g. 255 regroups all
classes and 5 regroups Voice and FAX
<time> 1-30 Time, rounded to a multiple of five seconds
Response
If <mode>=2 and command is successful
+CCFC:<status>,<class1>[,<num>,<type>[,,,<time>]][<CR><LF>
+CCFC:....]
OK/ERROR/+CME ERROR
Parameter
<status>
0
Inactive
1 Active