Specifications

AT Command Set for L55 Platform 2003-11-21
Copyright Siemens AG 2003 All Rights Reserved Page 36 of 131
2.3.4.7 AT+CLVL
AT+CLVL Loudspeaker volume level
Test command
AT+CLVL=?
Response
+CLVL: (list of supported <level>s)
OK
Read command
AT+CLVL?
Response
+CLVL: <level>
OK/ERROR/+CME ERROR
Write command
AT+CLVL=<level>
Response
OK/ERROR/+CME ERROR
Parameter
<level>
Loudspeaker Volume Level
2.3.4.8 AT+CMEC
AT+CMEC Mobile Termination control mode
Test command
AT+CMEC=?
Response
+CMEC: (list of supported <keyp>s),(list of supported <disp>s),(list of
supported <ind>s)
OK/ERROR/+CME ERROR
Parameter
<keyp>
0
MT can be operated only through its
keypad (execute command of AT+CKPD
cannot be used)
2 MT can be operated from both MT keypad
and TE
<disp> 0 only MT can write to its display
<ind> 0 only MT can set the status of its indicators
Read command
AT+ CMEC?
Response
+CMEC: <keyp>,0,0
OK/ERROR/+CME ERROR
Parameter
<keyp>
See Test command
Write command
AT+ CMEC=[<keyp>[,0[,0]]]
Parameter
<keyp>
See Test command
Response
OK/ERROR/+CME ERROR