2.3.4.12 AT+CPBR
AT+CPBR Read a telephone-book entry
Test command
AT+CPBR=
?
Response
+CPBR: (list of supported <index>s), <nlength>, <tlength>
OK/ERROR/+CME ERROR
Parameter
<index>
Location number
<nlength> Max. length of telephone number
<tlength> Max. length of text corresponding to the number
Write command
AT+CPBR=<index1>[,<index2>]
Response
+CPBR: <index1>, <number>, <typ>, <text>[<CR><LF>
+CPBR: .....
+CPBR: <index2>, <number>, <typ>, <text>]
OK/ERROR/+CME ERROR
Parameter
<index1>
Location number where the read of the entry starts
<index2> Location number where the read of the entry ends
<number> Telephone number
<typ> Type of number
<text> Text corresponding to the telephone number
<text> depends on AT+CSCS.
Note: In the <text> field, special characters like the following may appear
`"` (0x22), `@` (0x00), `ò` (0x08), `Ö` (0x5c).
See also section AT+CPBW and Appendix A: “Using special characters
in certain commands ( e. g., +CPBR/+CPBW”).
Empty entries do not produce any output.