AT Command Set for L55 Platform 2003-11-21
Copyright Siemens AG 2003 All Rights Reserved Page 90 of 131
2.4.2.2 AT^SBNR
AT^SBNR Binary Read
Test command
AT^SBNR=?
Response
^SBNR: (list of supported <types>s, (list of supported
<subtype>s))
OK/ERROR/+CME ERROR
Parameter:
<type>
see AT^SBNW command
<subtype> see AT^SBNW command
Write command
AT^SBNR=<type>,<subtype>
Response
^SBNR: <type>,<subtype>,1,<maxNumber>
<CR><LF><data><CR><LF>
^SBNR: <type>,<subtype>,2,<maxNumber>
<CR><LF><data><CR><LF>[...]
OK/ERROR/+CME ERROR
Parameter:
<type>
see AT^SBNW command
<subtype> see AT^SBNW command
<data> data in hexadecimal form (PDU)
<maxNumber> see AT^SBNW command
See “Appendix B” for examples