SCALANCE W770/W730 1 ___________________ Information on the Internet 2 ___________________ Introduction SIMATIC NET Industrial Wireless LAN SCALANCE W774-1/W734-1 Operating Instructions 3 ___________________ Description 4 ___________________ Mounting 5 ___________________ Connection 6 ___________________ Technical data 7 ___________________ Dimension drawings ___________________ 8 Approvals 09/2015 C79000-G8976-C325-06
Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
Contents 1 Information on the Internet ...................................................................................................................... 5 2 Introduction ............................................................................................................................................. 7 3 4 5 6 2.1 Information on the Operating Instructions ................................................................................ 7 2.2 Structure of the type designation .......
Contents SCALANCE W774-1/W734-1 4 Operating Instructions, 09/2015, C79000-G8976-C325-06
Information on the Internet 1 Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der Kompaktbetriebsanleitung in Ihrer Sprache im Internet: http://support.automation.siemens.com/ww/view/at/10806097 http://support.automation.siemens.com/ww/view/ch/10806097 http://support.automation.siemens.com/ww/view/de/10806097 http://support.automation.siemens.com/ww/view/li/10806097 http://support.automation.siemens.
Information on the Internet http://support.automation.siemens.com/ww/view/hk/10806097 http://support.automation.siemens.com/ww/view/sg/10806097 Kérjük, vegye figyelembe az interneten található, az Ön anyanyelvén íródott kompakt használati útmutatóban található figyelmeztetéseket és további információkat: http://support.automation.siemens.com/ww/view/hu/10806097 Skoðið vel viðvaranir og aðrar upplýsingar í notkunarleiðbeiningunum á ykkar tungumáli á internetinu: http://support.automation.siemens.
2 Introduction 2.1 Information on the Operating Instructions Validity of the Operating Instructions These operating instructions cover the following products: Article no. of the RoW version Article no.
Introduction 2.2 Structure of the type designation License conditions Note Open source software Read the license conditions for open source software carefully before using the product. You will find license conditions in the following documents on the supplied data medium: ● DOC_License_74.pdf ● DOC_LicenseScalanceW_76.htm 2.2 Structure of the type designation The type designation of the device is made up of several parts that have the following meaning: 2.
Description 3.1 3 Components of the product The following components are supplied with the product: ● SCALANCE W774 or SCALANCE W734 ● 2 protective caps for the antenna sockets ● 1 connector for the supply voltage (only with device variant RJ-45) ● 3 protective caps for the M12 sockets (only with device variant M12) ● 1 screw for mounting on an S7-300 standard rail or S7-1500 standard rail ● SIMATIC NET Industrial Wireless LAN CD Please check that the consignment you have received is complete.
Description 3.2 LED display LED Color Meaning L1 Green Power supply L1. L2 Green Power supply L2. PoE Green Power supply using Power over Ethernet. P1 Green There is a connection via the first Ethernet interface (Link). Green and yellow flashing alternately Data transfer via the first Ethernet interface. Green There is a connection via the second Ethernet interface (Link). Green and yellow flashing alternately Data transfer via the second Ethernet interface.
Description 3.3 Reset button 3.3 Reset button The reset button (position ①) is on the top of the housing: Functions of the reset button The reset button has the following functions: ● Restart of the device To restart the device, press the Reset button briefly. Note If you make changes to the configuration and restart immediately afterwards with the reset button, the changes may be lost.
Description 3.
4 Mounting CAUTION Minimum distance to antennas Fit the device so that there is a minimum clearance of 20 cm between antennas and persons. WARNING If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 °C.
Mounting 4.1 Wall mounting 4.
Mounting 4.1 Wall mounting Procedure Secure the device to the wall with two screws. The screws are not supplied with the device. The type and length of the screws depend on the type of wall.
Mounting 4.2 Installing on an S7-300 standard rail 4.2 Installing on an S7-300 standard rail Procedure WARNING Danger of injury by falling objects When used in an area with heavy load, the device is not adequately supported on an S7300 standard rail. Under such conditions, the device can come out of the mounting. If you use the device in a heavy load area, mount it on an S7-1500 mounting rail or on the wall. Follow the steps below to fit the SCALANCE W774/W734 to an S7-300 standard rail: 1.
Mounting 4.3 Installing on an S7-1500 standard rail 4.3 Installing on an S7-1500 standard rail Procedure Follow the steps below to fit the SCALANCE W774/W734 to an S7-1500 standard rail: 1. Place the device on the upper edge of the S7-1500 standard rail as shown in the figure. 2. Screw the housing to the S7-1500 standard rail. The required screw ships with the device.
Mounting 4.4 Installing on a DIN rail / removing 4.4 Installing on a DIN rail / removing Procedure for installation Follow the steps below to fit the SCALANCE W774/W734 to a DIN rail: 1. Place the device on the upper edge of the DIN rail as shown in the figure. 2. Press the device against the DIN rail until the DIN rail slider catch locks in place.
Mounting 4.4 Installing on a DIN rail / removing Procedure when removing Follow the steps below to remove the SCALANCE W774/W734 from a DIN rail: 1. Pull the DIN rail slider down with a screwdriver. 2. Tilt the SCALANCE W774/W734 forward and remove the device from the DIN rail.
Mounting 4.
5 Connection 5.1 Lightning protection, power supply and grounding Lightning protection WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system. When implementing your lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305 standard.
Connection 5.1 Lightning protection, power supply and grounding Note We recommend that you use the maintenance-free lightning protector LP798-2N. Exception: When there is also DC power supplied via the antenna cable. In this case, only the lightning protector LP798-1N can be used. WARNING Danger due to lightning strikes Installing this lightning protector between an antenna and a SCALANCE W700 is not adequate protection against a lightning strike.
Connection 5.1 Lightning protection, power supply and grounding Grounding WARNING Danger to life from overvoltage, fire hazard When using outdoor antennas, the shared or even grounded pin of the circuit must be connected to the shield of the coaxial cable and with all touchable conductive parts and circuits. Otherwise, in the event of a fault there may be illegally high voltages on touchable parts.
Connection 5.1 Lightning protection, power supply and grounding General notes on use in hazardous areas according to UL-HazLoc WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or nonhazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only.
Connection 5.2 Power supply 5.2 Power supply Note Galvanic isolation of the power supply unit To ensure dielectric strength according to IEEE 802.3, the supplying 24 V power supply unit must be galvanically isolated with a dielectric strength of 1500 VAC. The galvanic isolation must also not be bridged by other devices connected to the same power supply unit.
Connection 5.2 Power supply SCALANCE W774 M12 EEC For the power supply, there are two options with the SCALANCE W774 M12 EEC: ● Direct feed in via the four-pin M12 socket (position ①) ● Power over Ethernet via the M12 Ethernet interface P2 (position ②). The other Ethernet interface P1 is not capable of PoE.
Connection 5.2 Power supply The SCALANCE W774/W734 RJ-45 devices support the standards IEEE 802.3at type 1 (IEEE 802.3af ) and IEEE 802.3.at type 2. Note Disabling the PoE power supply Before you pull a plug via which the device is supplied with power using PoE, disable the relevant PoE power supply. Note "Phantom power" only with SCALANCE W774 M12 EEC The SCALANCE W774 M12 EEC device only supports the standard IEEE 802.3 at type 2.
Connection 5.3 Ethernet 5.3 Ethernet The SCALANCE W774/W734 devices have two Ethernet interfaces located on the underside of the device. Depending on the version, either RJ-45 or M12 sockets are available. SCALANCE W774/W734 RJ-45 ① ② Ethernet interface P1 Ethernet interface P2 The power can also be supplied via this interface (Power over Ethernet).
Connection 5.3 Ethernet SCALANCE W774/W734 M12 EEC ① ② Ethernet interface P1 Ethernet interface P2 The power can also be supplied via this interface (Power over Ethernet).
Connection 5.4 Suitable cables for power supply and Ethernet 5.4 Suitable cables for power supply and Ethernet Cable specification The following table lists the requirements for a cable depending on the application. Application Specification Direct 24 VDC supply • Round cable cross-section with 6 to 8 mm diameter. Two-wire cable with 0.5 to 1.5 mm2 cross-section per wire. • Permitted tensile load at least 100 N. • UL listing: Type PLTC or ITC Ethernet 1.
Connection 5.5 Antenna connectors 5.5 Antenna connectors The SCALANCE W774/W734 has two antenna connectors of the type R-SMA located on the top of the device. ① ② Antenna connector R1 A1 Antenna connector R1 A2 Procedure Follow the steps below to connect a cable for an external antenna to a SCALANCE W774/734: 1. Insert the connector on the antenna cable into the R-SMA socket and tighten the sleeve nut on the socket (key size SW8, tightening torque 0.6 Nm).
Connection 5.6 Suitable antenna cables and antennas Note Cabinet installation When installing the SCALANCE W770/W730 in a cabinet, you need to use detached antennas. Suitable connecting cable for a connection between SCALANCE W770/W730 and a detached antenna are available from SIMATIC NET. You will find detailed information in the following section. 5.
Connection 5.6 Suitable antenna cables and antennas ANT793-6DG Wide angle antenna, mast/ wall mounting, 9 dBi 5 GHz, 2 x N-Connect female 6GK5 793-6DG00-0AA0 ANT795-6MN Omni antenna, mounted on roof/vehicle, 6/8 dBi 2.4 GHz and 5 GHz, N-Connect female 6GK5 795-6MN10-0AA6 ANT795-4MC Omnidirectional antenna, 3/5 dBi, 2.4 GHz and 5 GHz, IP65, N-Connect male for direct installation on the device, straight connector. 6GK5 795-4MC00-0AA3 ANT795-4MD Omnidirectional antenna, 3/5 dBi, 2.
Connection 5.6 Suitable antenna cables and antennas Note ANT793-8DK The antenna ANT793-8DK may only be used with the antenna cable 6XV1875-5CN10 (10 m length). Other antenna cables are not permitted. Notice for USA/Canada Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2).
Connection 5.7 Replacing the PLUG (C-PLUG or KEY-PLUG) 5.7 Replacing the PLUG (C-PLUG or KEY-PLUG) How it works If a new C-PLUG or KEY-PLUG with a valid license is inserted in a SCALANCE W786, the configuration stored locally on the device is saved on the PLUG. If an incorrect PLUG, for example from another product or a damaged plug is inserted, the device signals an error with the red LED. The user then has the choice of either removing the PLUG again or selecting the option to reformat the PLUG.
Connection 5.7 Replacing the PLUG (C-PLUG or KEY-PLUG) Removing the PLUG Figure 5-1 Position of the slot for PLUG on the top of the SCALANCE W774/734 Follow the steps below to remove a PLUG from the device: 1. Turn off the power to the device. 2. Release the screw slot cover (position ①) and swing the slot cover to the side (position ②). 3. Insert a screwdriver between the front edge of the PLUG (Position ③) and the slot and release the PLUG. 4. Remove the PLUG from the slot. 5.
Connection 5.7 Replacing the PLUG (C-PLUG or KEY-PLUG) Licenses on the KEY-PLUG A C-PLUG only stores information about the configuration of a device.
Connection 5.
6 Technical data 6.1 Technical specifications W774/W734 RJ-45 The following technical specifications apply to the following devices: ● SCALANCE W774-1 RJ-45 ● SCALANCE W734-1 RJ-45 Note You will find detailed information on the transmit power and receiver sensitivity in the document "Performance data 802.11 abgn SCALANCE W770/W730" on the supplied data medium (REF_W770-RadioInterface.pdf). Technical specifications Data transfer Ethernet transfer rate 10 / 100 Mbps Wireless transmission rate 1 ...
Technical data 6.1 Technical specifications W774/W734 RJ-45 Technical specifications Wireless interface Antenna connector Quantity 2 Design R-SMA female Impedance 50 Ω nominal Frequency range 2412 ... 2480 MHz 4920 ... 5875 MHz Electrical data Power supply Supply voltage from terminal block/socket 24 VDC Safe Extra Low Voltage (SELV) Permitted range 19.2 to 28.
Technical data 6.1 Technical specifications W774/W734 RJ-45 Technical specifications Mean time between failure (MTBF) at 40 °C ambient temperature 61.85 years *) The PoE class depends on the hardware version of the device. Devices with a hardware version ≥ 3 have PoE class 2. Devices with a lower hardware version have PoE class 3.
Technical data 6.2 Technical specifications W774 M12 6.2 Technical specifications W774 M12 The following technical specifications apply to the following devices: ● SCALANCE W774-1 M12 EEC Note You will find detailed information on the transmit power and receiver sensitivity in the document "Performance data 802.11 abgn SCALANCE W770/W730" on the supplied data medium (REF_W770-RadioInterface.pdf). Technical specifications Data transfer Ethernet transfer rate 10 / 100 Mbps Wireless transmission rate 1 .
Technical data 6.2 Technical specifications W774 M12 Electrical data Power supply Supply voltage from terminal block/socket 24 VDC Safe Extra Low Voltage (SELV) Permitted range • 19.2 to 28.8 VDC • 16.8... 31.2 VDC (UL approvals only valid for 19.2 ... 28.
Technical data 6.
Dimension drawings 7 SCALANCE W774/734 RJ-45 SCALANCE W774-1/W734-1 Operating Instructions, 09/2015, C79000-G8976-C325-06 45
Dimension drawings SCALANCE W774 M12 EEC SCALANCE W774-1/W734-1 46 Operating Instructions, 09/2015, C79000-G8976-C325-06
8 Approvals You will find the approvals of the products in the reference work "Approvals SCALANCE W700 802.11n" on the Internet pages of Siemens Industry Online Support: ● Using the search function: support.automation.siemens.com (http://support.automation.siemens.com/WW/view/en) Enter the entry ID of the relevant manual as the search item. ● In the navigation panel on the left-hand side in the area "Industrial Communication": Industrial communication (http://support.automation.siemens.
Approvals SCALANCE W774-1/W734-1 48 Operating Instructions, 09/2015, C79000-G8976-C325-06
Index A L Antennas Connectors, 31 Specification, 32 Article numbers, 7 Assembly DIN rail, 18 S7-1500 standard rail, 17 S7-300 standard rail, 16 Wall mounting, 14 LED display, 9 Lightning protection, 21 Loading firmware, 11 P Power over Ethernet, 25 Power supply, 25 Primary user (radar), 9 Protective caps, 9 C Cables Permitted lengths, 39, 42 Specification, 30 Connectors, 9 C-PLUG, 35 D Dimension drawing, 45 Documentation on the CD, 7 R Reset button, 11 Resetting the device, 11 Restart of the device,
Index SCALANCE W774-1/W734-1 50 Operating Instructions, 09/2015, C79000-G8976-C325-06