3 Function diagrams
3.9 Setpoint channel
Fig. 3-69 3080 – Ramp-function generator selection, status word, tracking
- 3080 -
Function diagram
87654321
fp_3080_97_01.vsd
Setpoint channel
G120 CU230P-2
07.04.2014 V4.7
Ramp-function generator selection, status word, tracking
[3070.8]
1
Hochlaufgeber-Zustandswort
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Bit
0
1
xy
[3080.8]
[3050.8]
[2522.7]
[3070.3]
<1>
<2>
(p2148)
t
x,y x
y
T1
[3070.8]
From the extended ramp-function generator
n_set_5
Interpolator
Ramp-function generator tracking
Ramp flattening-off
Ramp-function generator status
word
Ramp-up active
Ramp-down active
Ramp-function generator active
Ramp-function generator set
Ramp-function generator held
Ramp-function generator tracking active
Maximum limiting active
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Behavior of the response ramp of the torque limiting:
p1145 = 0.0: No ramp-function generator tracking. The ramp-function generator ramp is no longer in the range of the
frequency actual value.
p1145 = 1.0: The ramp-function generator ramp remains as close as possible to the speed actual value.
p1145 > 1.0: The ramp-function generator ramp is steeper than for p1145 = 1.0 (higher "speed following error").
For p1145 > 0, ramp-function generator tracking is activated when the torque limiting
responds. This means that the speed controller output only exceeds the torque limit by a
deviation that can be set via p1145.
ZSW n_ctrl
r1407
r1407
RFG track intens
0.0 ... 50.0
p1145 [D] (0.0)
r1170
n_ctrl setp sum [rpm]
RFG ZSW
r1199
r1199
RFG ZSW
r1199
r1199
RFG ZSW
r1199
r1199
Ramp-function generator selection
[3070.8]
.5
.2
<1>
<2>
.7
[6030.1]