Service and maintenance
6.1 Maintenance
PM230 Power Module, IP55
44 Hardware Installation Manual, 12/2016, A5E35319202B AB
Changing the internal fan FSA … FSC
No tools are required to change the fan.
Preparation
1. Switch off the inverter.
2. Wait at least 5 minutes until the Power Module has fully discharged.
3. Remove the front cover of the inverter.
Procedure
1. Remove the power plug of the fan ①.
2. Press the holding clips of the fan module downward
②.
3. Remove the fan module from the guide rail
③.
4. Insert the new fan module until the holding clip locks in with a click
④.
5. Insert the power plug of the fan module
⑤.
6. Re-attach the front cover of the inverter.
Now you have changed the fan.
6.1.2.2
Replacement of the fans for the frame sizes FSD ... FSF
Changing the external fan FSD … FSF
To change the fan, you will need a Torx screwdriver, size 20.
Preparation
1. Switch off the inverter.
2. Wait at least 5 minutes until the Power Module has fully discharged.