Specifications

3.2 Assembly of the SINUMERIK 810D
3-40
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
DC link
rails
1
1
CCU3
CCU box
PE conductor connection
Battery
–X307
Fig. 3-3 Assembly of the SINUMERIK 810D
Pay attention to the following when installing the SINUMERIK 810D:
1. Cooling clearance top and bottom, approx. 100 mm
2. The shields of the motor cables must be connected after mounting the
shield sheet, see section 2.1.3.
3. The equipotential bonding conductor must be connected for each motor.
4. Additional mounting depth is required for mounting the connector.
5. The tightening torque of the screws must be complied with.
6. The screws of the DC link busbars must all be tightened.
Installation
instructions
3 Desi
g
n and Installation of the 810D