Specifications

4.2 Interfaces
4-56
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
SIMODRIVE 611D-Drive bus interface and I/O extension
Connector name: X130
Connector type: 36-pole Micro Ribbon
Maximum cable length: 10 m
Special features: non-isolated (no safe isolation)
Device bus interface (power supply)
Connector name: X151
Connector type: 34-pole ribbon cable connector, male
Connection for axis expansion plug-in unit
Connector name: X304, X305, X306
Connector type: 20-pole ribbon cable connector, male
Pulse interface for axis 3
Connector name: X307
Connector type: 20-pole ribbon cable connector, male
Measuring sockets for output of 3 analog signals. The measuring values
that are output are assigned in the software.
Connector name: X341, X342, X351, X352
Connector type: Measuring socket 2 mm
Table 4-7 Assignment of the measuring sockets X341 to X352
Measuring socket Position on the
CCU
Meaning Section
X351
DAC 1 0– 5V
X352
DAC 2 0– 5V
X341
DAC 3 0 – 5V
X342
Ground for all DACs
6 x measuring system connection for indirect and direct position sensing
Connector name: X411-X416
Connector type: 25-pole, D-Sub male connector
Signals with a gray background are not required for a direct measuring system.
X130
X151
X304, X305, X306
X307
X341, X342,
X351, X352
X411-X416
4 Descri
p
tion of the SINUMERIK 810D