Specifications

5.1 Axis expansion plug-in unit
5-79
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
Table 5-1 Connection of the ribbon cable connector to the axis expansion plug-in
unit
Ribbon cable connector 1-axis power module 2-axis power module
X301 1st axis 1st axis
X302 Unassigned 2nd axis
1. Bring in and connect the ribbon cable for connector X301 through the slot in
the front panel with the notch facing forward.
2. If applicable, also attach the ribbon cable for connector X302 accordingly
(for 2nd axis).
Ribbon cable
X301
X302
Notch
Sheet-metal cover Axis expansion plug-in unit
Front panel
301 302
Fig. 5-3 Connection of the ribbon cables to the axis expansion
3. After plugging in the axis expansion plug-in unit and connecting to the CCU,
you should push the excess cable length in the space provided for that pur-
pose under the sheet-metal cover of the axis expansion plug-in unit.
Installation
5 Axis Ex
p
ansion