Specifications
5.2 Axis expansion with SIMODRIVE 611D control plug-in unit
5-80
Copyright © Siemens AG 2006
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
5.2 Axis expansion with SIMODRIVE 611D control plug-in
unit
Axis expansion with SIMODRIVE 611D control plug-in unit is only used if the
number of measuring channels of the SINUMERIK 810D is insufficient, or
higher performance is required.
The SIMODRIVE 611D module must be inserted as the first module to the right
of the SINUMERIK 810D. If DC link busbars are connected, all screws must be
tightened firmly (comply with tightening torque, see figure 3-4).
A special set of cables is required to connect the SIMODRIVE 611D control
module. This cable set contains the connection with the drive bus and another
device bus cable.
SIMODRIVE
810D
(CCU3)
LDCPower supply
(I/R or OI)
SIEMENS
611D control plug-in unit
Cable set:
Device bus and drive bus
Fig. 5-4 Axis expansion for SINUMERIK 810D with the SIMODRIVE 611D module
Application
Mounting
Connection
5 Axis Ex
p
ansion