SIMATIC RTLS PCB OEM AC Introduction 1 Device description 2 SIMATIC RTLS Installation & Operation 3 Localization systems SIMATIC RTLS PCB OEM AC Technical specifications 4 Approvals 5 Operating Instructions 03/2020 C79000-G8976-C519-03
Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
Table of contents 1 Introduction ............................................................................................................................................. 5 2 Device description................................................................................................................................... 9 3 2.1 Safety notices ........................................................................................................................... 9 2.
Table of contents SIMATIC RTLS PCB OEM AC 4 Operating Instructions, 03/2020, C79000-G8976-C519-03
Introduction 1 Purpose of the Operating Instructions These operating instructions support you when installing and connecting up the SIMATIC RTLS PCB OEM AC device. The configuration and the integration of the devices in a network are not described in these operating instructions.
Introduction Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support offers support at the following Internet address: (https://support.industry.siemens.com/cs/start?lc=en-US) Apart from news, there you will also find: ● Project information: Manuals, FAQs, downloads, application examples etc. ● Contacts, Technical Forum ● The option submitting a support query: (https://support.industry.siemens.
Introduction To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under: (https://support.industry.siemens.com/cs/us/en/ps/15247/pm) Recycling and disposal The products are low in harmful substances, can be recycled and meet the requirements of the Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE). Do not dispose of the products at public disposal sites.
Introduction SIMATIC RTLS PCB OEM AC 8 Operating Instructions, 03/2020, C79000-G8976-C519-03
2 Device description 2.1 Safety notices NOTICE Avoid contact with the RTLS transponder Avoid contact (e.g. with your hands) with the RTLS transponder in order to avoid contamination of and resulting damage to the RTLS transponder. NOTICE Precautionary measures against electrostatic discharge The RTLS transponder can be damaged by electrostatic discharge (ESD). Take suitable precautionary measures when unpacking and operating the transponder to avoid damage. 2.
Device description 2.3 Pin assignment 2.3 Pin assignment P2 socket Type: JST SM02B-SRSS-TB Pin Description / Function 1 3.3 V supply voltage 2 GND P1 connector Internal interface for production and manufacturing test, do not use. 2.4 LED status indicator The operating states of the transponder are indicated by the LEDs. The states can be off , on and flashing .
Device description 2.5 Dimension drawing 2.5 Dimension drawing The UWB antenna is arranged diagonally standing up on the top side of the PCB.
Device description 2.
Installation & Operation 3.1 3 Notes on installation Note Before you install the devices, read this section carefully to ensure trouble-free installation and commissioning. The devices can only be used in conjunction with the RTLS localization system. An adhesive label with the serial number is attached to the transponder. The transponder is installed in an enclosure so that it is no longer visible (e.g. electric screwdriver).
Installation & Operation 3.
4 Technical specifications Table 4- 1 Technical specifications of the transponder RTLS PCB OEM AC 6GT2700-8DF00-0AX1, 6GT2700-8DF10-0AX1 6GT2700-8DF20-0AX1, 6GT2700-8DF30-0AX1 Product name SIMATIC RTLS PCB OEM AC PULSE radio frequencies (localization) Wireless method IEEE 802.15.4-2011 UWB Transmission speed 850 kbit/s Operating frequency rated value 3993.6 MHz (UWB channel 2; CE, FCC) 6489.6 MHz (UWB channel 5; CE, FCC, IC, CMIIT) Bandwidth 499.2 MHz Frequency range 3100 MHz ...
Technical specifications 6GT2700-8DF00-0AX1, 6GT2700-8DF10-0AX1 6GT2700-8DF20-0AX1, 6GT2700-8DF30-0AX1 Permitted ambient conditions Ambient temperature • During write/read access • 0 ... +50 °C • Outside write/read access • 0 ... +50 °C • During storage • 0 ... +50 °C Design, dimensions, weights and connectors Dimensions of board (L x W x H) 25 x 25 x 18 mm Dimensions of antenna (L x W x H) 20.6 x 12.7 x 1.
5 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.
Approvals Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems ● ETSI EN 301 489-33 Electromagnetic compatibility and radio spectrum ma
Approvals Article 3 (2) Efficient use of the radio spectrum ● ETSI EN 300 328 Wideband transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques. Harmonized standard covering the essential requirements of article 3.2 of the EU Directive 2014/53/EU ● ETSI EN 302 065-2 Short Range Devices (SRD) using ultra-wideband technology (UWB); Harmonized standard covering the essential requirements of article 3.
Approvals label can use wording such as the following: "Contains Transmitter Module FCC ID: NXWOEMAC" or "Contains FCC ID: NXWOEMAC". Any similar wording that expresses the same meaning may be used. RF Exposure guidance In order to comply with FCC RF Exposure requirements, this device must be installed to provide at least 20 mm separation from the human body at all times.
Approvals RF Exposure guidance In order to comply with ISED RF Exposure requirements, this device must be installed to provide at least 20 mm separation from the human body at all times. Instructions relatives à l'exposition aux RF Pour être conforme aux exigences de la ISED relatives à l'exposition aux radiofréquences, ce matériel doit être installé de manière à assurer à tout moment une distance d'au moins 20 mm du corps humain.