SIMATIC RTLS PCB OEM PULSE Introduction 1 Device description 2 SIMATIC RTLS Installation & Operation 3 Localization systems SIMATIC RTLS PCB OEM PULSE Technical specifications 4 Approvals 5 Operating Instructions 03/2020 C79000-G8976-C552-03
Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
Table of contents 1 Introduction ............................................................................................................................................. 5 2 Device description................................................................................................................................... 9 3 2.1 Safety notices ........................................................................................................................... 9 2.
Table of contents SIMATIC RTLS PCB OEM PULSE 4 Operating Instructions, 03/2020, C79000-G8976-C552-03
Introduction 1 Purpose of the Operating Instructions These operating instructions support you when installing and connecting up the SIMATIC RTLS PCB OEM PULSE device. The configuration and the integration of the devices in a network are not described in these operating instructions.
Introduction Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support offers support at the following Internet address: (https://support.industry.siemens.com/cs/start?lc=en-US) Apart from news, there you will also find: ● Project information: Manuals, FAQs, downloads, application examples etc. ● Contacts, Technical Forum ● The option submitting a support query: (https://support.industry.siemens.
Introduction To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under: (https://support.industry.siemens.com/cs/us/en/ps/15247/pm) Recycling and disposal The products are low in harmful substances, can be recycled and meet the requirements of the Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE). Do not dispose of the products at public disposal sites.
Introduction SIMATIC RTLS PCB OEM PULSE 8 Operating Instructions, 03/2020, C79000-G8976-C552-03
2 Device description 2.1 Safety notices NOTICE Avoid contact with the RTLS transponder Avoid contact (e.g. with your hands) with the RTLS transponder in order to avoid contamination of and resulting damage to the RTLS transponder. NOTICE Precautionary measures against electrostatic discharge The RTLS transponder can be damaged by electrostatic discharge (ESD). Take suitable precautionary measures when unpacking and operating the transponder to avoid damage. 2.
Device description 2.3 Pin assignment 2.3 Pin assignment Solder contact P4 Pin Description / Function 1 Grounding 2 Rx - Input on the transponder, 3.3 V 3 Tx - Output on the transponder, 3.3 V 4 Supply voltage 3.3 V P1 connector The individual pins are connected to the solder contacts (P4). Type: JST SM04B-SRSS-TB Pin Description / Function 1 Rx - Input on the transponder, 3.3 V 2 Tx - Output on the transponder, 3.3 V 3 Grounding 4 Supply voltage, VCC, 3.
Device description 2.5 Dimension drawing 2.5 Dimension drawing The antenna is connected to the PCB via a 5 cm long U.FL cable. The contacts used are P3 on the PCB and P1 on the antenna. PCB Figure 2-1 All dimensions specified in millimeters. Figure 2-2 All dimensions specified in millimeters.
Device description 2.
Installation & Operation 3.1 3 Notes on installation Note Before you install the devices, read this section carefully to ensure trouble-free installation and commissioning. The devices can only be used in conjunction with the RTLS localization system. An adhesive label with the serial number is attached to the transponder. The transponder is installed in an enclosure so that it is no longer visible (e.g. electric screwdriver).
Installation & Operation 3.
4 Technical specifications Table 4- 1 Technical specifications of the transponder RTLS PCB OEM PULSE 6GT2700-8AF03, 6GT2700-8AF13 6GT2700-8AF23, 6GT2700-8AF33 Product name SIMATIC RTLS PCB OEM PULSE PULSE radio frequencies (localization) Wireless method IEEE 802.15.4-2011 UWB Transmission speed 850 kbit/s Operating frequency rated value 3993.6 MHz (UWB channel 2; CE, FCC) 6489.6 MHz (UWB channel 5; CE, FCC, CMIIT, IC) Bandwidth 499.2 MHz Frequency range 3100 MHz ...
Technical specifications 6GT2700-8AF03, 6GT2700-8AF13 6GT2700-8AF23, 6GT2700-8AF33 Degree of protection IP00 Method of securing PCB: 3 screws, Ø 1.
5 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.
Approvals Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-33 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 33: Specific conditions for ultra-wideband (UWB) devices ● EN 55011 Industrial, scientific and medical equipment - Radio-frequency distu
Approvals FCC information Siemens SIMATIC RTLS PCB OEM PULSE (MLFB 6GT2700-8AF13); FCC ID NXWOEMPULSE This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Approvals IC information Siemens SIMATIC RTLS PCB OEM PULSE (MLFB 6GT2700-8AF33); IC ID 267XOEMPULSE This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence.