System information

Polycom, Inc. 7–1
7
Feature Limitations
The following table lists the known feature limitations for this release. If a
workaround is available, it is noted in the table.
Issue ID
Found in
Release Description Workaround
VIDEO-89476 HDX software
3.0.1
When an HDX system that is TCP-registered to
OpenScape Voice is restarted, it might not delete its
registration to OpenScape Voice as it is supposed to.
None
VIDEO-88989 HDX software
3.0.1
OpenScape
Video V3 R2
When an HDX system and a TANDBERG C60 are both
TCP-registered to OpenScape Video, and the C60
calls the HDX system, dual video might not display.
None
VIDEO-88824 HDX software
3.0.1
OpenScape
Desktop client
V3R2
The HDX system might use the incorrect ports when
receiving a call from the OpenScape Desktop client
over the transport layer security (TLS) protocol using
Multimedia Internet KEYing (MIKEY).
None
VIDEO-87603 HDX software
3.0.1
A problem monitoring SNMP might occur in the HDX
system when operating in a Siemens OpenScape UC
environment.
None
VNGR-21180 RMX 7.2.1 In some situations, calls to the RMX cannot be
completed and the TCP connection cannot be
established.
None
VNGR-20918 RMX 7.2 If an RMX separates from the network, you cannot
configure the network service for the recording link.
Configure the default
H.323 IP network
service to the same
settings as the RSS
network.
VNGR-20855 RMX 7.2 Sometimes during a conference, active SIP
participants are not released if the RMX is reset.
None