s 5 701 Web server TM TM For Synco , Synco OZW772.. V9.0 living Web server OZW772.. allows for remote plant control and monitoring via the web and Smartphone App. Four versions of the web server OZW772.. are available: To connect 1, 4, 16, or 250 Synco devices from product ranges Synco 700, room controllers RXB/RXL, RDG/RDF/RDU room thermostats, and the QAX9… Synco living central apartment units. • Operate web browser via PC/laptop or Smartphone.
• Function "Energy indicator" for monitoring data points for energy-technical limit values, so-called “Green limits", and sending them to 2 e-mail recipients • Web services for external applications via Web API (Web Application Programming Interface) • Encrypted with https and TLS for e-mails (all connections). • ACS790 functionality.
Access in Synco IC via OZW gateway Web server OZW772.. can also be used as a gateway for remote operation of the M-bus web server WTV676-HB6035 in Synco IC. Before accessing the M-bus web server, you must register in Synco IC and configure and activate the OZW gateway. Once the OZW gateway is activated, you can no longer access the OZW web page via Synco IC.
User interface web server (Direct connection) In the web server user interface, the user symbol the Synco IC portal symbol . and user name are in place of 4 / 26 Siemens Building Technologies Web Server OZW772.. V9.
User interface portal Synco IC Click the symbol to open the web server user interface under a new tab and is then the same as the view under a direct connection. The Synco IC portal symbol symbol and user name. and e-mail address is displayed in place of the user 5 / 26 Siemens Building Technologies Web Server OZW772.. V9.
Primary navigation Primary navigation offers the following functions: Home Energy indicator Faults File transfer User accounts Device web pages Menu-based plant and device operation. Display and operating of "Energy indicator" data points (Displayed only if a controller is connected with an Energy indicator) Display system faults. Create and manage trend functions Download consumption data and message history, upload documents, logos, and system definitions as well as firmware update User administration.
System report System messages The web server generates system reports and periodically sends the system operating state to e-mail recipients. Messages are sent as per the set time (hh:mm), message cycle interval (1...255 days), and priority (urgent/non-urgent). Connection test Press the button on the web server to send a system report to all defined e-mail recipients regardless of fault priority.
Visualize plants Web server OZW772.. allows for visualizing technical equipment (HVAC, electrical, energy values) in buildings via plant web pages. For example, a plant web page can be set up visualizing a plant with data points (max. 100 data points per plant web page) on a floor plan. In the event of a fault, users can quickly access the impacted locations. Double-click writable parameters to open a dialog box and edit the value.
Download plant diagrams You can download web-capable plant diagrams from the HIT online platform for standard applications on Synco 700 devices, room controllers RXB/ RXL, and room thermostats RDG/RDF/RDU. Create own plant web pages You can freely design plant web pages. As a hybrid form, you can also modify and extend downloaded plant diagrams. Web page elements Users can also embed additional data in a plant diagram such as energy values (version 5.
Trend function The trend function can be defined directly in the web server OZW772.. as of version 5.0. Any number of data points for connected devices can be logged at a selectable sample rate and queried using the trend function. Data points for devices integrated via KNX S-Mode are also available for the trend function. Trend channels 5 trend channels are available: Each trend channel can include up to 100 data points. The trend channel can be labeled using a plain text name.
Trend graph The data for a trend channel can be graphically displayed on the web user interface. The function is available for OZW772.. as of version 6.0. Data transmission per e-mail Up to 2 e-mail recipients can be defined for the trend data. Each trend channel can send its data to one or both e-mail recipients. The send interval can be set individually for each trend. Import/Export Trend definitions can be imported to the web server or exported from the web server.
Consumption data trending The "consumption trend" function is available in web server OZW772.. as of version 3.0. The following devices are supported: • Synco 700: RMU7x0B, RMH760B, RMK770 (as of version 2.0), RMS705, RMS705B, RMB795, RMB795B • Synco living: Central apartment unit QAX903, QAX913 OZW772.. as of version 5.0 Energy and volume meters that use KNX data points are supported with the integration of KNX S-Mode as of web server version 5.0.
Function "Energy indicator" The "Energy indicator" function is available in web server OZW772.. as of version 4.0. The following devices are supported: • Synco 700: RMS705B, RMU7x0B, RMH760B, RMK770 (as of version 2.0), RMB795B Central apartment unit QAX903, QAX913, QAX910 (as of version 3.
Web services The "Web Application Programming Interface" (Web API) is an interface to provide web services client to the web server. All web API functions are started via "http" or encrypted with "https". Each session starts with authentication at the web server. If "Home Control IC” App is installed on a smartphone, the app accesses, using the web services, via web API, data points for devices on the KNX network (Communication connection for smartphone, see page 14).
Equipment combinations The following Synco devices can be connected to the web server OZW772.. Synco range Synco devices Universal controllers Heating controllers Boiler sequence controllers Central control units Switching & monitoring units Bus operator unit Room unit Central communication unit RMU7x0, RMU7x0B RMH760, RMH760B RMK770, RMK770 V2 RMB795, RMB795B RMS705, RMS705B RMZ792 QAW740 OZW771, OZW775 Data sheet no.
Technical design Web browser Devices PC/Laptop (1024 x 786) Requirements html5 compatible web browser. Smartphone Specific for device Number of browsers Any number of browsers can be used simultaneously. The maximum data throughput rate is distributed among the browsers. Operation slows down as the number of users increases accordingly. Operation, monitoring, alarming Communication connections for local commissioning (USB) and remote operation, remote monitoring and alarming via Ethernet.
Interfaces USB The USB interface directly connects the PC/laptop on site. The required USB cable type A – type Mini-B is delivered with the device. Ethernet The router/network is connected to the Ethernet RJ45 plug. The Ethernet interface features Auto-MDI(X) for crossed and non-crossed Ethernet cables. An Ethernet category 5 cable is supplied. KNX The KNX bus is connected to the CE+ and CE− connection terminals labeled "KNX". See data sheet N3127 for more information on the KNX bus.
Execution Basic design The web server consists of a housing lower section containing printed circuit boards with interfaces. The upper housing section covers the printed circuit boards. The upper housing section contains the LED displays and one operating button. The connection terminals and additional display and operating elements are located under the removable cover for the upper housing section. All display and operating elements are labeled.
Button combinations and • Long (> 6 s) Simultaneously press and restores default factory settings. All configuration data and settings are reset. The device list, plant diagrams, and unsent messages are deleted. History data is not deleted. Notes Mounting The Web server can be mounted in a panel, distribution box, or on a wall. Include space for wiring when planning. Make sure service can easily access the unit and the unit is ventilated properly.
Commissioning Connections The web server is commissioned using a web browser and, as an option, with ACS790. Web server connects to the PC/Laptop via USB with the supplied USB cable or over Ethernet. You can connect via Synco IC as an alternative. Additional information is included in the Mounting Instructions M5701 or the Installation guide G5701 and the Commissioning instructions C5701 in the download center at http://www.siemens.com/ozw772-manual.
Disposal The device is considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage. • Use only proper channels to dispose the device. • Comply with all local, applicable laws and regulations. 21 / 26 Siemens Building Technologies Web Server OZW772.. V9.
Technical data Power cable for web server OZW772.. Web server OZW772.. Function data KNX bus USB Ethernet Directives and standards Operating voltage Rated voltage "Euro plug" AC 230 V ±15 % AC 230 V EN 50075 and VDE 0620-1 Frequency 50 / 60 Hz Power consumption (including web server OZW772...) 3 VA typical Protection class II Output voltage SELV 24 VDC Fusing of supply lines Max. 16 A Cable length (distance from AC 230 V plug to web server) Max. 1.
Degree of protection IP30 to EN 60529. Protection class III as per EN 60950-1. Operation Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions IEC 60721-3-3 Class 3K5 0 …50 °C 5…95% r. h. (non-condensing) Class 3M2 Transport Climatic conditions Temperature Humidity Mechanical conditions IEC 60721-3-2 Class 2K3 −25...+70 °C < 95% r.h. Class 2M2 Upper housing section PC + ASA, RAL 7035 (light-gray) Lower housing section PC + ASA, RAL 5014 (dove blue).
Connection diagrams Connection diagram KNX connection terminals Pin assignment DC 24 V plug 1 2 24 VDC (+) GND (–) 24 / 26 Siemens Building Technologies Web Server OZW772.. V9.
Dimensions 25 / 26 Siemens Building Technologies Web Server OZW772.. V9.
Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Theilerstrasse 1a 6300 Zug Switzerland Tel. +41 58-724 24 24 www.siemens.com/buildingtechnologies © Siemens Switzerland Ltd 2018 Delivery and technical specifications subject to change 26 / 26 Siemens Building Technologies Web Server OZW772.. V9.