Selection & Application Guide PL and ES Series Load Centers™ usa.siemens.
PL and ES Series Load Centers™ Table of Contents Description Page Catalog Numbering System 2 Siemens PL and ES Series Load Centers Overview 3 PL Series 1-Phase Main Lug & Main Breaker Load Centers 4 PL Series 1-Phase Special Application Load Centers 5 PL Series 3-Phase Main Lug & Main Breaker Load Centers 6 PL Series 3-Phase Unassembled Load Centers 7 ES Series 1-Phase Main Lug & Main Breaker Load Centers 8 ES Series 1-Phase Unassembled Load Centers 9 ES Series 1-Phase Special Load Center
Load Centers Catalog Numbering System Catalog Numbering System P 12 24 Type Enclosure or Component E G W I or PI R P S PW SW = = = = = = = = = Indoor Type 1 2-10 and 30-42 circuits 300-400Amp Indoor Type 1 12-42 circuits Outdoor Type 3R Interior Riser PL Series Indoor Type 1 12-70 circuits ES Series Indoor Type 1 12-70 circuits PL Series Outdoor Type 3R 12-70 circuits ES Series Outdoor Type 3R 12-70 circuits Spaces Maximum number of 1" breakers Circuits Maximum number of circuits Type of Mai
Load Centers Siemens PL and ES Series Load Centers™ Overview ES Series: PL Series: Convertible Invertiblea Insta-wire neutrals & grounds Ground bars included Copper busbars Dual neutrals on all configurations Carton-in-carton packaging Lifetime warranty PL Series 1-phase NEW PL Series 3-phase Invertiblea Insta-wire neutrals & grounds Aluminum busbars Single sided neutral on 24 circuits and below Single piece carton packaging 10 year warranty ES Series 1-phase ES Series
PL Series 1-Phase Main Lug & Main Breaker Load Centers 1-phase, 3-wire SN, 120/240 Volts AC Main Breaker/Convertible Load Centers 12-70 Circuits / 100-225 Amperes Copper Bus 60/75°C Rated, 22,000A IR Indoor Enclosure – NEMA Type 1 Amp Rating No. of Spaces No. of Circuits PL Catalog Number No. of Circuits PL with WireGuide Interior Catalog Number NEMA 1 Enclosure Height (inches)c Outdoor Enclosure – NEMA Type 3R NEMA 3R No.
PL Series 1-Phase Special Application Load Centers 1-phase, 3-wire SN, 120/240 Volts AC Split Ground Series Main Lug Convertible Load Centers Copper Bus 12-60 Circuits / 125-200 Amperes 60/75°C Rated, 100,000A IR Branch Circuits Amp Rating No. of Spaces No.
PL Series 3-Phase Main Lug & Main Breaker Load Centers 3-phase, 3-wire, 240 Volt AC or 3-phase, 4-wire, 120/240 or 120/208 Volts AC Copper Bus 60/75°C Rated, 22,000A IR Main Breaker/Convertible Load Centers 30-70 Circuits / 100-225 Amperes Branch Circuits Amp Rating Indoor Enclosure – NEMA Type 1 No. of Spaces No.
PL Series 3-Phase Unassembled Load Centers 3-phase, 3-wire, 240 Volt AC or 3-phase, 4-wire, 120/240 or 120/208 Volts AC Copper Bus 60/75°C Rated, 22,000A IR Main Breaker Convertible Unassembled Load Centers 24-70 Circuits / 100-225 Amperes Interiors Enclosure Trim Kit Amp Rating No. of Spaces No. of Circuits Interior Catalog Number Enclosure Height (inches) Enclosure Catalog Number No.
ES Series 1-Phase Main Lug & Main Breaker Load Centers 1-phase, 3-wire SN, 120/240 Volts AC Main Breaker 12-70 Circuits / 100-225 Amperes Aluminum Bus 60/75°C Rated, 22,000A IR Indoor Enclosure – NEMA Type 1 Amp Rating 100 No. of Spaces 10 12 16 20 30 12 16 125 24 30 150 16 20 24 30 200 225 40 16 20 24 30 40 42 54 42 54 No.
ES Series 1-Phase Unassembled Load Centers 1-phase, 3-wire SN, 120/240 Volts AC Features Available for the most popular ES Load Centers Gives the ability to order in bulk Enclosures will have minimal packaging for less hassle and waste at the job site Keeps the covers separate to prevent damage or theft Includes full size cardboard covers to keep the interior safe during painting All main lug panels include factory installed ground bars Main Breaker ES Unassembled Load Centers 24-40 Circuits
ES Series 1-Phase Special Load Centers 1-phase, 3-wire SN, 120/240 Volts AC First Surge ES Load Centers 54-60 Circuits Amp Rating No. of Spaces No. of Circuits Aluminum Bus 60/75°C Rated, 22,000A IR Surge Protection Catalog Number Enclosure Height (inches) 200 30 54 S3054B1200S060 60kA 36 200 40 60 S4060B1200S060 60kA 42 Outdoor Trailer Panels 16 Circuits / 200 Amperes Aluminum Bus 60/75°C Rated, 100,000A IR No. of Amp Rating Spaces No.
ES Series 3-Phase Main Lug & Main Breaker Load Centers 3-phase, 3-wire, 240 Volt AC or 3-phase, 4-wire, 120/240 or 120/208 Volts AC Main Breaker 30-60 Circuits / 100-225 Amperes Aluminum Bus 60/75°C Rated, 10,000A IR Branch Circuits No. of Amp Rating Spaces No.
EQ® Load Centers—300-400 Amp 1-Phase, 3-Wire/3-Phase, 3-Wire, 4-Wire Features E3030MB1400SCU UL listed for 60/75°C conductors. See equipment markings for applications. Copper bus standard. Factory installed lock on indoor enclosure. Outdoor enclosures use HV type hubs. See page 1-22. Main Breaker 300-400 Amperea 1Ø, 3-Wire 120/240 Volts AC Branch Circuits Type QP Ampere Rating Max. 1-Pole Max. 2-Poles Indoor Enclosure — NEMA Type 1 (65,000A IR) Dimensions (inches) Catalog Std.
Generator Ready Load Centers 1-Phase, 3-WIre SN, 120/240 Volts AC Generator Ready Load Centers The Siemens generator ready load center can save thousands of dollars in future generator installation expenses while keeping initial expenses to a minimum. Works with an automatic standby generator or a portable generator.
Riser Panel Load Centers 1-Phase, 3-WIre SN, 120/240 Volts AC Riser Panel Load Centers Riser panel load centers are ideal for high rise applications. The shifted interior provides room for conductors to pass through the load center. The tap kits allow the installer to tap off from those conductors to power the panel. Features UL Listed for use in 1Ø and 3Ø riser gutter applications. C opper bus standard. M ain lug factory standard - convertible to main breaker.
EQ® Load Centers—Small Circuit Load Centers 1-Phase, 3-WIre SN, 120/240 Volts AC Features/Applications EQ Load Centers with main lugs feature a combination trim box in one package. Interiors offer removal in seconds Single phase One piece bus bar construction designed for use only with circuit breakers UL Listed UL listed on 60/75°C conductors (see equipment markings for applications) Positive load side circuit breaker hook rails Outdoor Type 3R devices use HS Type hubs. See page 1-22.
EQ® Load Centers—Circuit Breaker Enclosures 1-Phase and 3-Phase, 240V AC Max. Features Circuit breaker enclosures range from 60A to 250A, indoor and outdoor models Designed for use exclusively with QP, QT, QPH, HQP, BQ, BQH, HBQ, QPP, QPPH, HQPP, QR2, QRH2, HQR2, and HQR2H circuit breakers UL listed Suitable for use as service entrance equipment UL listed for 60/75°C conductors (See equipment markings for applications) Outdoor type 3R devices use HS type hubs (pg.
Load Centers Load Center OEM Interiors 1Ø: Small Circuit Main Lug Interiors Amps 60 60 125 125 125 200 200 Catalog Numberb I0204ML1125CU I0303ML3100CU I0408ML1125 I0816ML1125CU I0816ML1125CUSP I0202L1200 I1220L1200CT Spaces 2 3 4 8 8 4 12 Circuits 2 3 8 16 16 4 20 Dimensions Height 4.40 5.77 4.51 6.19 6.19 3.88 9.00 Width 1.85 3.42 6.61 6.81 6.81 7.13 7.
Load Centers Load Center Accessories Catalog Number Description Pack Qty Ground Bar Kits (For ES and PL Load Centers) EC1GB8 EC1GB82 EC2GB12 EC2GB122 EC2GB15 EC2GB152 EC3GB21 EC3GB212 EC3GB27 EC3GB272 EC3GB30 EC3GB302 EC3GB352 EC3GB352G GROUND BAR KIT-8 POS GROUND BAR KIT-8 POS, 2/0 LUG GROUND BAR KIT-12 POS GROUND BAR KIT-12 POS, 2/0 LUG GROUND BAR KIT-15 POS GROUND BAR KIT-15 POS, 2/0 LUG GROUND BAR KIT-21 POS GROUND BAR KIT-21 POS, 2/0 LUG GROUND BAR KIT-27 POS GROUND BAR KIT-27 POS, 2/0 LUG GROUND
Load Centers Load Center Accessories Lug Kit, 3-Pole, Subfeed or Feed thru Applications ECLK3225 Main Breaker Retainer Kit for EQ Load Centers ECMBR1 Ground Bar Kit, ECGB14 Add-A-Lock (Flush Lock) ECQFL1 For EQ load centers 2 PH Main Lug Conversion Kit 150A-225A ECMLK225 Main Breaker Kit 200A - 225A, 1PH 22K MBK200A 3-Pole Main Breaker Kit MBK3200 Main Breaker Retainer kit for PL, ES, & Ultimate Load Centers ECMBR2 Neutral Lug Kit, ECLK1-2 wire range — #2-1 AWG Cu or Al Filler Plate, ECQF3 Ground
Load Centers Load Center Accessories Load centers and meter combos Touchsafe barriers are required for any single main service entrance application for a panel covered under UL 67. Line Terminal Barriers will be included in Main Breaker Load Centers and Single Main Meter Combos manufactured after January 1, 2017. Single phase and 3-phase main breaker kits will include a barrier.
Murray Load Centers Features All main breakers are straight in wiredno backfeeding required. Outboard neutral and groundbars allow for all nuetral and ground connections to be located away from the breaker connections, making for a neat, clean installation All devices are convertible from main lug to main breaker or vice versa with the addition of main breaker or main lug kits. “Swiss Cheese” style neutral bars provide multiple 1/0 connection points.
Murray Load Centersa Main Lug & Main Breaker Load Centers 1-phase, 3-wire SN, 120/240V ACb Main Lugs with Aluminum Bus 12-60 Circuit, 125-225 Amperes 100,000A IR Dimensionsd Height Width Amps Max. No.
Murray Rock Solid Load Centers Accessories Hubs ECHS125 Catalog Number Descripttion Pack Quantity ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 ECHS250 3⁄4” Hub 1” Hub 11⁄4” Hub 11⁄2” Hub 2” Hub 21⁄2” Hub 10 10 10 10 10 10 Catalog Number Descripttion Pack Quantity ECLX388HD For use on MP-T, MP-HT, & MP-MT breakers in Rock Solid Load Centers For use on MP-T, MP-HT, & MP-MT breakers in 2–8 circuit Load Centers For use on MD-T, MD-HT, & MD-MT breakers on old style (pre 2003) load centers (12–42 circuit)
Notes 24 Siemens Industry, Inc.
Published by Siemens 2018 Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 Siemens Technical Support: 1-800-333-7421 info.us@siemens.com Printed in USA Order No. RPSA-ESPLS-0818-CP All Rights Reserved © 2018, Siemens Industry, Inc. usa.siemens.com/loadcenters The technical data presented in this document is based on an actual case or on as-designed parameters, and therefore should not be relied upon for any specific application and does not constitute a performance guarantee for any projects.