Data Sheet for Product
17
Smart Infrastructure
A6V11940275_en--_b
2021-03-12
Technical data
Extras
SD card
PCA2002-A1
PCA2017-A1
Ordering
Preferred
Second source
Supply
Power supply
2.7…3.6 V
2.7…3.6 V
Current consumption
<50 mA
<110 mA
Cycle frequency
50 Mhz max.
50 Mhz max.
Performance data
Storage capacity
2 GB
2 GB
Number of insertions
At least 10,000 insertions
At least 20,000 insertions
Data storage period
10 years
10 years
Service life
10,000 sequences
(read/write/delete)
10,000 sequences
(read/write/delete)
Shock resistance
1000 G
1500 G
Vibration
Maximum 15 G peak-to-peak
Maximum 50 G peak-to-peak
Resistance
Water-tight
Dust-tight
ESD protection
Interfaces
Plug-in contacts
8 pins
Ambient conditions
Operating temperature
0…+70 °C
-25...+85 °C
Storage temperature
0…+70 °C
-25...+85 °C
Operation in humid
environments
(without moisture
condensation)
10...90 % rel.
10...85 % rel.
Storage in humid
environments
(without moisture
condensation)
5...90 % rel.
5...85 % rel.
Dimensions and weights
W x H x D mm
11 x 1 x 15 (+/- 0.1)
Weight
0.4 g