Configuration Instructions

Hardware specific configuration
'Logic Outputs Connector'
7
154 | 219
A6V10429097_en--_e
Function
Description
'Logic Operation Inputs'
Used to perform a boolean logic operation on a logic input and display the result
on a digital output.
'Parameter
Input/SysVarID/
Feed/Level/LED
'
This parameter is a bitmask, which is able to address eight
inputs and outputs, e.g., 6 (00000110) input 2 and 3 active.
'Audio Out/In'
This parameter represents the position of the bitmask
0
IO 1 to 8
1
IO 9 to 16
2
IO 17 to 24
3
IO 25 to 32
'LED Mode'
Choose the boolean logic operation, output will switch high if:
OR
at least one input/output is logic high
AND
all of the inputs/outputs are logic high
MT
more than the configured number of elements
are logic high (limit is 5 IOs)
EQU
the state of the IOs matches the selected
mask (limit is 3 IOs)
'Logic Operation Outputs'
Used to perform a boolean logic operation on a digital output and display the
result on a digital output (parameters as above for 'Logic Operation Inputs')
'System Value'
System-specific value is above the limit. Valid parameters are:
'LED Mode'
Defines the system value:
0
Enabling the output via AVC value and limit
'StationID'
Defines the station
'Input/SysVarID/
FeedNo/Level'
AVC limit in dB
'Follow Logic Output'
The logic output follows another logic output within the system. Valid parameters
are:
'Audio Out/In'
Defines the logic output (all physical outputs are supported)
'StationID'
Defines the station