Technical data for loop, amplifier and audio matrix
Maximum number of speaker loops:
Per amplifier channel 2
PC2003-A1, audio matrix 8
PC2003-A1, audio matrix, supplied with
internal pilot sound
4
Maximum number of loop isolators (100 V) per audio matrix PC2003-A1:
Per loop 80
All loops 480
Maximum number of loop isolators (100 V) per amplifier output:
1x 150 W (PV2003-A1) 80
1x 250 W (PV2001-A1, PV2007-A1) 80
1x 300 W (PV2003-A1 bridge mode) 80
1x 500 W (PV2001-A1 bridge mode,
PV2002-A1)
80 with 1 loop
120 with 2 loops
Amplifier power calculation for loop isolator (100 V)
Per loop isolator (100 V) 0.5 W
Maximum audio payload (according to calculation method below):
1)
1x 150 W (PV2003-A1) 110 W with 80 loop isolators (100 V)
1x 250 W (PV2001-A1, PV2007-A1) 210 W with 80 loop isolators (100 V)
1x 300 W (PV2003-A1 bridge mode) 260 W with 80 loop isolators (100 V)
1x 500 W (PV2001-A1 bridge mode,
PV2002-A1)
460 W with 80 loop isolators (100 V)
440 W with 120 loop isolators (100 V)
Connections
Design Spring type
Cable diameter Min.: 0.75 mm²
Max.: 2.5 mm²
Loudspeaker cable:
2)
Maximum cable length per amplifier output 1000 m
Cable types, untwisted only FP30/60 NYM, 2 x 1.5 mm²
ISTY 2 x 2 x 0.8 mm²
Ambient conditions
Operating temperature -5…+40 °C
Storage temperature -20…+70 °C
Operation in humid environments
(without moisture condensation)
10...90 % rel.
Storage in humid environments
(without moisture condensation)