Configuration Instructions
System configuration
System limits
5
42 | 219
A6V10429097_en--_e
Loop isolator
● Max. number of isolators per amplifier:
– 150 W: 80
– 200 W: 80
– 250 W: 80
– 300 W: 80
– 500 W: 80
● Max. number of isolators per matrix PC2003/PC1001/PC1002: 480
● Max. 80 loop isolators per line
● No combination with EOL3 and loops on a station
● Minimum ↑ tapping* of speaker connected to loop isolator: 0.75 W
* Tapping: 100 V speakers have a transformer upstream of the chassis. The
transformer has several taps on the primary side, which is where the 100 V
speaker line is connected. These taps determine how much power is drawn by
the speaker. With a 100 V signal, ceiling speakers typically draw a power of 6 W,
3 W, 1.5 W, or 0.75 W. Halving the electrical power leads to a 3 dB reduction in
the audio signal.
Digital outputs
● The 'Test & Quit key' input enables all outputs on the matrix.
● The 'Remote Logic Input' function is restricted to the first 32 inputs.
● The 'Local Logic Input' function is restricted to the first 32 inputs.
● Outputs for logic operations are restricted to the first 32 inputs.
● 'GP_OUT:' Only 1…32 can be used via the ↑ API.
Analog inputs
● PC2003 and Cerberus PACE Compact digital audio matrix board: The analog
inputs of the PCIO2001 are displayed as inputs 1…8.
● When there is a second PCIO2001 on the same 'PACE-Bus', the analog inputs
are displayed as inputs 9…15.
● PC2001/2002: The analog inputs of the PCIO2001 are displayed as inputs
9…15.
'ControlledBy' function of the audio outputs
● Digital inputs/outputs are restricted to 1…8.
● Analog inputs 1…15 can be used.
– Input 16 cannot be used.
● Full use of this function cannot be made if a PT2006 is used for the output.
Macros
A recursive macro is a macro that includes another macro within it and calls this
other macro.
● It is possible to have a recursive macro that calls a button already assigned to
a macro.
● Up to five recursive macro calls are supported.
'ErrorLogging'
● ↑ RSL is restricted to 512 active stations.
● Only the first 24 inputs can be logged when 'logEvents' is active.