Configuration Instructions

Administration and system monitoring
Graphical user interface
9
A6V10429097_en--_e
173 | 219
Designation
Explanation
DigIn
Displays the current state of all digital inputs.
DigOut
Displays the current state of all digital outputs.
Analog In
Displays the analog input voltage 0...10 V of the local
device. The voltage is displayed in [%] and a corresponding
gain value in [dB] when the voltage is used to control the
sound level.
Input Prefade
Analog level of the input signal
Input Postfade
Digital level of the input signal after the signal processing
FeedNetwork
Level of the network program channel sent into the network
Audio Output
Analog signal level of the local output
AVC
If the automatic volume control (AVC) algorithm is enabled,
this gain value will be used by all outputs, which have the
AVC value enabled in their signal line.
Speaker Line x
If the 'LineDetection' function is enabled on the 'Supervision'
tab, the 'LineDetection' state of all used speaker lines is
shown.
Backup information
Will be shown if backup control is enabled on the
'Supervision' tab.
Information on the backup amplifier supervision and if any of
the local outputs have switched to backup mode is
displayed.