Siemens Schweiz AG User Manual CE1U2354en
HVAC Products Room unit QAA55… 23. August 2007
3.6 Room unit QAA55…
Engineering
@
The room unit should be located in the main living room while giving consideration to
the following points:
• The place of installation should be chosen so that the sensor can capture the room
temperature as accurately as possible without getting adversely affected by direct
solar radiation or other heat or refrigeration sources (about 1.5 meters above the floor)
• In the case of wall mounting, there must be sufficient clearance above the unit,
enabling it to be fitted and removed
When the unit is removed from its base, power is cut off so that the unit is out of
operation.
Mounting method
2284Z33a
2284Z34a
• The controller must not be exposed to dripping water
Connections
1
34
562
2284 Z40
1 CL+ BSB data
2 CL- BSB ground
Dimensions and drilling plan
2282M02
96
9
6
9
1
4
7
12
2359Z27
4,2
56
60
56
60