User Manual

20 / 134
Siemens Synco™ living CE1C2740en
Building Technologies Commissioning the system 13.12.2010
Select the Commissioning menu
From the “Main menu“ of the central apartment unit, select submenu “Com-
missioning“ and confirm the selection by pressing the Menu/ok button.
Caution!
Plant stops
You are notified that the plant is being
stopped. Confirm by pressing the
Menu/ok button to shut down the plant
and go to the ”Commissioning“ menu.
Commissioning
Basic configuration…
RF connections…
Device list…
Bus communication…
You are now in the “Commissioning “
menu – the plant has been stopped.
It is switched on again only when you
manually exit the ”Commissioning ”
menu by pressing the Esc button (no
timeout).
Configure rooms
Activate the required rooms by selecting a heating/cooling type other than “---“
or by activating function ”Supervision only“.
Main menu > Commissioning > Basic configuration
> Rooms > Room X > Heating type:
--- Inactive – all relevant room heating informa-
tion and all operating lines are hidden.
(Factory setting)
Radiator heating slow Radiator heating in buildings with massive
walls, heavy construction.
Radiator heating fast Radiator heating in buildings with light
walls, light construction.
Floor heating slow Floor heating in buildings with massive
walls, heavy construction and massive floor
construction.
Floor heating fast Floor heating in buildings with light walls,
light construction and light floor construction.
Rad/floor user-defined Control parameters can be manually set.
Air conditioner (S-mode) For rooms with an air conditioner used for
heating.
Usually, the standard heating types are enough. Customize settings
only in plants with greatly differing control behavior (see page 99).