User Manual

57 / 124
Siemens Synco™ living CE1C2707en
Building Technologies Commissioning the system 23.08.2008
For detailed information, refer to the documentation covering the
GAMMA wave products.
The door / window contact is connected by pressing the multifunction button
on the door or window contact for at least one second. If the learning tele-
grams were forwarded, the LED blinks for about 3 seconds.
To confirm the successful connection, the central apartment unit delivers a
beep. When all devices of the room are connected, close the binding process
by pressing the Menu/ok button.
Connect smoke detectors
When connecting smoke detectors, they are always assigned to a room.
Inform the central apartment unit which room you want to assign a smoke
detector:
Main menu > Commissioning > RF connections
> Smoke detector > Room X > Connect device:
The DELTA reflex smoke detector is automatically switched on as soon as the
inserted batteries supply power.
For detailed information, refer to the documentation supplied with the
smoke detector.
The smoke detector is connected by pressing the button on the front of the
detector for at least 2 seconds and then pressing the binding button at the rear
for at least 1 second. Then, the LED at the rear blinks several times.
To confirm the successful connection, the central apartment unit delivers a
beep. Close the binding process by pressing the Menu/ok button.
Smoke detectors must be equipped with the smoke detector module
wave UNI M 255. For detailed information, refer to the documentation
covering the GAMMA wave products.
Connect RRV934 multi-controllers
The multi-controller is automatically switched on as soon as power is applied.
Then, the LEDs are tested. All LEDs light up for one second. The mains LED
lights up when the unit is ready to operate.
As long as none of the multi-controller channels is connected, the binding LED
flashes. All other LEDs remain dark.
When you press the binding button, the state of the individual chan-
nels is indicated. The LEDs of the channels already connected light
up while the LEDs of the non-connected channels remain dark. When
releasing the button, the multi-controller returns to normal operation
after 7 seconds. When one of the channels is selected, the binding
LED indicates the state of the respective channel / channel group.