User Manual

67 / 124
Siemens Synco™ living CE1C2707en
Building Technologies Commissioning the system 23.08.2008
After the battery test, the device changes directly to normal operation. The
LED extinguishes again.
F
LED
2707Z18
Now, press multifunction button F on the
meteo sensor. The LED lights up in
accordance with the batteries’ capacity
(green: Bat. ok, red: Bat. not ok). When
the LED starts blinking, you can release
the binding button.
F = multifunction button
LED = light emitting diode
Now, the binding LED on the device blinks green and extinguishes on suc-
cessful completion of the binding process with the central apartment unit.
To confirm the successful connection, the central apartment unit delivers a
beep. Close the binding process by pressing the Menu/ok button.
The device is now connected and performs normal operation.
Connect lighting and blinds actuators
RF adapter plugs and GAMMA wave lighting and blinds actuators can
only be assigned to switching groups which, beforehand, were set up
for the respective function. Refer to ”Configure the switching groups“
on page 32.
The lighting and
blinds actuators are switched on as soon as power is applied
to them.
When commissioning GAMMA wave light actuators, a lamp must be
connected. Otherwise, the actuators are not correctly powered, which
means that they cannot be connected.
On the central apartment unit, select the switching group which you want to
assign actuators:
Main menu > Commissioning > RF connections
> Switching groups > Switching group X > Connect device:
Confirm subentry “Connect device“ by pressing the Menu/ok button. To make
the connection, you are prompted to press the binding button on the device to
be connected.
Connect RF adapter plugs KRF960 and KRF961
Press the button on the RF adapter plug. The LED is permanently lit. Release
the button when it starts to blink. A successful connection appears on the
display of the central apartment unit and confirmed with a beep.