Building Technologies Central apartment unit QAX910 23.08.2008
Example of release according to the time switch and the twilight switch:
DA
BR
ABC DE FG
t
B2707Z02
On
Off
On
Off
On
Off
A
B
C
D
Time program presence simulation (On, Off)
Absence (On, Off)
Twilight (DA = DARK, BR = BRIGHT)
Release of simulation (On, Off)
t Time
Function
“Function” allows you to control switching groups by at random or constant
switch-on of a switching group. The setting is effective only if the presence
simulation of the corresponding switching group as described above is en-
abled.
Main menu > Switching groups > Switching group X > Presence simulation
> Function
The following settings are available:
Random The switching group actors are switched on or off
within the set period at random intervals of 3 to
30 minutes. The first switch-on of each switching
group also is at random. The switching points of the
individual switching groups differ.
Continuously
on (Contin on)
The switching group is switched on constantly. This
allows you to ensure that at least one light is on during
the presence simulation.
Switching group 1 2 3 4
Factory setting Random Random Random Random
Your setting Random
Contin on
Random
Contin on
Random
Contin on
Random
Contin on
Switching group 5 6 7 8
Factory setting Random Random Random Random
Your setting Random
Contin on
Random
Contin on
Random
Contin on
Random
Contin on
C
B
A
D