s 5 701 Web-Server TM For Synco , Synco TM OZW772... V5.2 living Web server OZW772… allows for remote plant control and monitoring via the web and Smartphone App. Four versions of the web server OZW772... are available: To connect 1, 4, 16, or 250 Synco devices from product ranges Synco 700, room controllers RXB/RXL, RDG/RDF/RDU room thermostats, and the QAX9… Synco living central apartment units. Operate web browser via PC/laptop or Smartphone.
Function "Energy indicator" for monitoring data points for energy-technical limit values, so-called “Green limits", and sending them to 2 e-mail recipients Web services for external applications via Web API (Web Application Programming Interface) Encrypted with https and TLS for e-mails. ACS790 functionality. Use Building Owners/operators End customers, HVAC and electrical installers. Real estate companies, real estate management companies.
Web interface The web server interface is the same using the portal or via a direct connection. The portal has, however, additional functions and available settings. User interface portal Click the symbol to open the web server user interface under a new tab and is then the same as the view under a direct connection. The portal symbol and user name.
Display The display range displays content corresponding to the selected primary and secondary navigation. Plant state The display indicates no fault or the most serious plant fault depending on plant state. Faults Fault sources The web server recognizes failures and fault signals from KNX devices contained in the device list. Own faults also are recognized. Fault display, fault acknowledgement The LED signals a fault on the web server . LED blinks to indicate that a fault is unacknowledged.
Visualize plants Web server OZW772... allows for visualizing technical equipment (HVAC, electrical, energy values) in buildings via plant web pages. For example, a plant web page can be set up visualizing a plant with data points (max. 100 data points per plant web page) on a floor plan. In the event of a fault, users can quickly access the impacted locations. Double-click writable parameters to open a dialog box and edit the value.
Download plant diagrams You can download web-capable plant diagrams from the HIT online platform for standard applications on Synco 700 devices, room controllers RXB/ RXL, and room thermostats RDG/RDF/RDU. Create own plant web pages You can freely design plant web pages. As a hybrid form, you can also modify and extend downloaded plant diagrams. Web page elements Users can also embed additional data in a plant diagram such as energy values V5.
Trend function The trend function is available in web server OZW772… as of V5.0. Any number of data points for connected devices can be logged at a selectable sample rate and queried using the trend function. Data points for devices integrated via KNX S-Mode are also available for the trend function. Trend channels 5 trend channels are available: Each trend channel can include up to 100 data points. The trend channel can be labelled using a plain text name.
Consumption data trending The "consumption trend" function is available in web server OZW772… as of V3.0. The following devices are supported: Synco 700: RMU7x0B, RMH760B, RMK770 (as of V2.0), RMS705, RMS705B, RMB795, RMB795B Synco living: Central apartment unit QAX903, QAX913 OZW772 as of V5.0 Energy and volume meters that use KNX data points are supported with the integration of KNX S-Mode as of web server V5.0.
Function "Energy indicator" The "Energy indicator" function is available in web server OZW772… as of V4.0. The following devices are supported: Synco 700: RMU7x0B, RMH760B, RMK770 (as of V2.0), RMS705B, RMB795B Synco living: Central apartment unit QAX903, QAX913, QAX910 (as of V3.
Web services The "Web Application Programming Interface" (Web API) is an interface to provide web services client to the web server. All web API functions are started via "http" or encrypted with "https". Each session stars with authentication at the web server. If "Home Control App" is installed on a smartphone, the app accesses, using the web services, via web API, data points for devices on the KNX network (Communication connection for smartphone, see page 12).
Equipment combinations The following Synco devices can be connected to the web server OZW772. Synco range Synco devices Universal controllers Heating controllers Boiler sequence controllers Central control units Switching & monitoring units Bus operator unit Room unit Central communication unit RMU7x0, RMU7x0B RMH760, RMH760B RMK770, RMK770 V2 RMB795, RMB795B RMS705, RMS705B RMZ792 QAW740 OZW771, OZW775 Data sheet no.
Technical design Web browser Devices PC/Laptop (1024 x 786) Smartphone Requirements Internet Explorer V10.0 or higher. Firefox V18.0 or higher. Specific for device Number of browsers Any number of browsers can be used simultaneously. The maximum data throughput rate is distributed among the browsers. Operation slows down as the number of users increases accordingly.
Logs Web operation Web operation via portal takes place through an HTTPS encrypted connection (Port 443) via TCP/IP. The required certificate is accredited. Web operation without portal takes place through an HTTPS encrypted connection (Port 443) via TCP/IP. The required certificate is not accredited. The self signed certificate by Siemens has saved on the web server for a period of 20 years. The certificate can be installed in the web browser as needed.
LED indication 1 (red/green/orange) Dark Steady red Flashing red Steady green Lit orange Flashing green green / orange No operating voltage DC 24 V Web server starts operating system. Web server starts application. Web server operational, "Energy indicator" = "Green leaf" Web server operational, "Energy indicator" = "Orange leaf" Web server operational, connected to the portal (LED 0.8 s on, 0.2 s off) Dark Lit Flashing No bus power. KNX operational. Communication on KNX.
Notes Mounting The web server can be mounted in a panel, distribution box, or on a wall. Include space for wiring when planning. Make sure service can easily access the unit and the unit is ventilated properly. Standard mounting Wall mounting Mounting position Mounting and dimensions On standard rail TH 35-7.5. Attached with 2 screws. Horizontal or vertical. See "Dimensions".
User groups User accounts are created and assigned to specific user groups for customized user operation. End user Access to end-user data and fault overview. Operate and monitor via menu tree and plant diagrams. Administer own user accounts. Service Same as end user. In addition: Access service data. Create, download, and manage trend data Download consumption data and message history. Upload customized logos and documents. System definitions update. Update device web pages.
Technical data Power cable for web server OZW772... Web server OZW772… Function data KNX bus USB Ethernet Directives and standards Operating voltage Rated voltage "Euro plug" AC 230 V 15 % AC 230 V EN 50075 and VDE 0620-1 Frequency 50 / 60 Hz Power consumption (including web server OZW772...) 3 VA typical Protection class II Output voltage SELV 24 VDC Fusing of supply lines Max. 16 A Cable length (distance from AC 230 V plug to web server) Max. 1.
Degree of protection Degree of protection IP30 to EN 60529. Protection class III as per EN 60950-1. Operation Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions IEC 60721-3-3 Class 3K5 0 …50 °C 5…95% r. h. (non-condensing) Class 3M2 Transport Climatic conditions Temperature Humidity Mechanical conditions IEC 60721-3-2 Class 2K3 25...70 °C < 95% r.h.
Connection diagrams Connection diagram KNX connection terminals Pin assignment DC 24 V plug 1 2 24 VDC (+) GND (–) Dimensions 2009-2014 2009 - 2012Siemens SiemensSwitzerland SwitzerlandLtd Ltd Siemens Building Technologies Web-Server OZW772... V5.