User Manual

4
Smart Infrastructure
A6V11562461_en--_a
2019-09-19
Topology
Notes:
1. Install the receiver close to RDS110.R if possible. The communication range in a building
is typically 60 m, without any blockades. Please note the range can vary, as walls, floors,
wireless interference and other factors may reduce the signal strength.
2. Add a repeater (RCR114.1) if the connection fails due to low signal strength (distance or
blockades (walls, etc.)).
3. The thermostat can only connect to one heating system so it cannot simultaneously
control the wireless relay and the valve actuator.
4. The thermostat can control up to six wireless relays or valve actuators.
Mechanical design
The room thermostat consists of the following parts:
Housing front with touch screen
Housing rear with terminals and temperature sensor
Metallic mounting plate for wall mounting
Accessories