User Manual
Connecting to wireless devices
Connecting to Smart Thermostat receivers
5
18
| 60
A6V11562455_en--_a
5.2 Connecting to Smart Thermostat receivers
The thermostat can connect to a maximum of six Smart Thermostat receivers
(RCR114.1 as a relay) to control the following heating equipment:
● Gas boiler
● Radiator with pump
● Electric floor heating
● Fan with electric heating
● Floor heating with valve
● Floor heating with pump
● Electric radiator
● Electric boiler
● Generic heating device
See Changing system setup [➙ 35] for more information about heating
equipment.
To initiate the connection with RCR114.1 Smart Thermostat Receiver
1. On the Home screen, tap , then tap and .
2. If prompted, enter the administrator password.
3. Tap > , and then tap Pair new devices.
4. On RCR114.1, press the button. The LED flashes green.
5. Perform the above action on all receivers if you have more than one RCR114.1
on hand.
On RCR114.1, the LED flashes green during connection establishment and
turns to green when it succeeds. If the connection fails, the LED is solid
yellow. Try to connect again.
The thermostat displays information about successful pairing.
6. Tap Done on the thermostat. All the added devices are displayed on the
Devices page.
5.3 Connecting to wireless valve actuators
The thermostat can connect to a maximum of six wireless valve actuators
(SSA911.01TH) to control Radiator with valve.
See Changing system setup [➙ 35] for more information about heating
equipment.
To initiate the connection with a wireless valve actuator
1. On the Home screen, tap , then tap and .
2. If prompted, enter the administrator password.
3. Tap > , and then tap Pair new devices.
4. On SSA911.01TH, press and hold down for more than two seconds. The
THREAD network symbol on the display of SSA911.01TH blinks.