User Manual

Turn on display lighting, check error messages or other important information
Press the Info button once to activate display backlighting. Backlighting goes off automatically
after a short time.
Continuing to press the Info button activates the information display: is lit.
The device first shows pending error messages and then important information (e.g. switching
programs, …).
Change the temperature level in the time switch program, or are you not at home for
a while?
In the time switch program, press this button to change from the current temperature level to
the next and back.
Quickly activate energy saving temperature when you leave the apartment briefly to save
energy.
The change appears on the display. It is valid only until the next switching time.
Select operating mode
Press the operating mode button to select one of 5 modes.
Operating modes with time program
The controller offers both time programs Automatic
and Exception day .
Do you feel too warm / too cold ?
Press or to set the temperature. The setting is temporary and active only until the next time
the controller activates a change.
Note: To set your own programs, see: "Enter customized temperatures and switching times".
Continuous operating modes
The controller offers continuous operating modes "Continuous comfort mode“ ,
"Continuous energy saving mode“
and protection mode (frost or overheating) .
Do you feel too warm / too cold ?
Press or to set a continuous temperature.
Enter customized temperatures and switching times
The controller has three different switching patterns that you can allocate to the weekday blocks 1-5, the
weekend block 6-7, or to the individual days 1…7.
Proceed as follows:
Select operating mode or .
Slider in position 3 (weekdays
, weekend , individual days ): Press
or to select the block (weekdays, weekend) or individual day.
Note: Making changes to individual days destroys the corresponding block.
You can only restore a destroyed block by Reset the controller.
Slider in position 4 (number of comfort phases): Press
or to set the number of
comfort phases.
Slider in position 5 (start time comfort phase 1): Press
or to set the start time.
Slider in position 6 (temperature comfort phase 1): Press
or to set the
temperature.
Slider in position 7 (end time comfort phase 1): Press
or to set the end time.
, ,
, ,
Slider positions 8…10 (comfort phase 2) and slider positions 11…13
(comfort phase 3): Same procedure as above for comfort phase 1.
Slider in position 14 (energy saving temperature in time switch programs Automatic and
Exception day): Press
or to set the temperature.
Note: The energy saving temperature is valid Monday through Sunday.
It does not depend on operating mode "Continuous energy saving".
RUN
Move the slider to RUN position and close the cover.
Notes (e.g. individual settings):
Enter holidays or absence
You can enter start, temperature and end of your holidays. The controller switches to the set
holiday temperature at the start of the holidays and back to the preset operating mode at the
end of the holidays.
During holiday mode, symbol
flashes and the end of the holidays is displayed.
Proceed as follows:
Slider in position 15 (start of absence): Press or to set the start of the holidays
(date).
Slider in position 16 (temperature during absence): Press or to set the
temperature effective during the holidays.
Slider in position 17 (end of absence): Press or to set the end of the holidays
(date).
RUN
Move the slider back to RUN. Symbol appears to the left of symbol . To quit
holiday mode prematurely, press
, , , or move the slider.
Reset to factory settings
Press and together with the operating mode button for 3 seconds. All
temperature and time settings are reset to default values. The clocks starts at 12:00.
Caution: All customized settings are lost !
Factory settings: Heating Factory settings: Cooling
, , ,
20 °C
, , ,
24 °C
,
16 °C
,
28 °C
8 °C
35 °C
12 °C
30 °C
Factory settings: Switching times
Comfort phases P1 P2 P3 P4 P5 P6
1. 07:00 23:00 PASS PASS PASS PASS
2. 06:00 08:00 17:00 22:00 PASS PASS
3. 06:00 08:00 11:00 13:00 17:00 22:00
Activate Party mode
You can activate Party mode only in operating modes and . In Party mode, the device
controls to any selectable temperature for any selectable time.
In Party mode, symbol
is displayed along with the end of Party mode.
Proceed as follows:
Test the radio connection
Press on the rear of the controller. The quality of the radio connection is displayed on the
controller display and on LED_2 of the receiver.
The test is automated. The controller shows the quality of the radio connection
for all connected receivers (max. 15) during 10 minutes:
The numbers next to "RCR“ designates the tested receiver.
The bar under numbers 0…9 shows the receiver's signal strength.
e.g.
Press
or to select a receiver; press , or to cancel the test.
The receiver shows the signal strength at LED_2. It is lit either green (very good reception),
orange (good reception), or red (bad or no reception). In the case of bad reception, reduce the
distance between room unit and receiver.
1. Press for 3 seconds.
2. Press or to set the duration for Party mode. Party mode can last
max. 9 hours. The entry is accepted after 20 seconds or when you press
.
3.
Press or to set the temperature.
4. Party mode ends automatically after the Party duration ends or when you press
or .
B2206en 25.12.2007 Siemens, Building Technologies