System Manual Part 1
Table Of Contents
- SIMATIC RF200
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF290R
- 6 Antennas
Readers
5.1 SIMATIC RF210R
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
107
5.1.6
Technical specifications of the RF210R reader
Table 5- 2 Technical specifications of the RF210R reader
6GT2821-1AC10
Product type designation
SIMATIC RF210R
Radio frequencies
Operating frequency, rated value
13.56 MHz
Electrical data
Maximum range
20 mm
Maximum data transmission speed
reader ↔ transponder
ISO tags
• Read • approx. 1500 bytes/s
• Write • approx. 1500 bytes/s
Typical transmission time for user data per byte
• for write access • 0.6 ms
• for read access • 0.6 ms
Transmission speed
19.2, 57.6, 115.2 kBd
Read/write distances of the reader
see section "Field data (Page 39)"
MTBF (Mean Time Between Failures)
505 years
Interfaces
Electrical connector design
M12, 8-pin
Standard for interfaces for communication
RS-422
Antenna
integrated
Mechanical specifications
Housing
• Material • Brass, nickel-plated
• Color • Silver
Recommended distance to metal 0 mm
Supply voltage, current consumption, power loss
Supply voltage 24 VDC
Typical current consumption 50 mA
Permitted ambient conditions
Ambient temperature
• During operation • -20 … +70 °C