System Manual

Table Of Contents
Planning the RF200 system
4.3 Installation guidelines
SIMATIC RF200
102 System Manual, 03/2019, J31069-D0227-U001-A11-7619
NOTICE
Maximum number of connectable antennas
Note that a maximum of two antennas can be operated on the RF285R readers by using an
antenna splitter. Use the RF290R reader for setups with more antennas.
Required components
For installation with
2 antennas (gate)
3 antennas (C arrangement)
4 antennas (tunnel)
the following components are required:
Table 4- 52 Components required for setting up with 2, 3 or 4 antennas
Number of required
components for setup
with
Component
Article number
2 ant.
3 ant.
4 ant.
1 1 1 Basic device:
RF290R (↔ CM or PC)
RF290R: 6GT2821-0AC12
optionally:
ASM 475: 6GT2002-0GA10
ASM 456: 6GT2002-0ED00
RF170C: 6GT2002-0HD00
RF180C: 6GT2002-0JD00
RF182C: 6GT2002-0JD10
RF18xC: 6GT2002-0JEx0
2 3 4 Antenna ANT D1 / D5 / D6 / D10 optionally:
ANT D1: 6GT2698-5AC00
ANT D5: 6GT2698-5AA10
ANT D6: 6GT2698-5AB00
ANT D10: 6GT2698-5AF00
2 3 4 With ANT D6 if required:
cover
6GT2698-5AD00
1
2
3
Antenna splitter
6GT2603-0AC00
1 1 1 Wide-range power supply unit for
SIMATIC RF systems
(for PC mode only)
EU: 6GT2898-0AC00
UK: 6GT2898-0AC10
US: 6GT2898-0AC20