System Manual
Table Of Contents
- SIMATIC RF200
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Planning the RF200 system
4.3 Installation guidelines
SIMATIC RF200
102 System Manual, 03/2019, J31069-D0227-U001-A11-7619
NOTICE
Maximum number of connectable antennas
Note that a maximum of two antennas can be operated on the RF285R readers by using an
antenna splitter. Use the RF290R reader for setups with more antennas.
Required components
For installation with
● 2 antennas (gate)
● 3 antennas (C arrangement)
● 4 antennas (tunnel)
the following components are required:
Table 4- 52 Components required for setting up with 2, 3 or 4 antennas
Number of required
components for setup
with …
Component
Article number
2 ant.
3 ant.
4 ant.
1 1 1 Basic device:
RF290R (↔ CM or PC)
RF290R: 6GT2821-0AC12
optionally:
ASM 475: 6GT2002-0GA10
ASM 456: 6GT2002-0ED00
RF170C: 6GT2002-0HD00
RF180C: 6GT2002-0JD00
RF182C: 6GT2002-0JD10
RF18xC: 6GT2002-0JEx0
2 3 4 Antenna ANT D1 / D5 / D6 / D10 optionally:
ANT D1: 6GT2698-5AC00
ANT D5: 6GT2698-5AA10
ANT D6: 6GT2698-5AB00
ANT D10: 6GT2698-5AF00
2 3 4 With ANT D6 if required:
cover
6GT2698-5AD00
1
2
3
Antenna splitter
6GT2603-0AC00
1 1 1 Wide-range power supply unit for
SIMATIC RF systems
(for PC mode only)
EU: 6GT2898-0AC00
UK: 6GT2898-0AC10
US: 6GT2898-0AC20