System Manual

Table Of Contents
Planning the RF200 system
4.4 Chemical resistance of the reader and transponders
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
111
Substance
Test conditions
Rating
Concentration [%]
Temperature [°C]
Lactic acid, w.
50%
20 ℃
++
10%
20 ℃
+++
10%
60 ℃
++
Sodium carbonate, w. (soda)
c. s.
60 ℃
++++
Sodium chloride, w.
c. s.
60 ℃
++++
Sodium hydroxide
-
60 ℃
++++
Nickel salts, w.
c. s.
60 ℃
++++
Nitrobenzene
-
20 ℃
+++
-
60 ℃
++
Phosphoric acid
10%
20 ℃
+
Propane
-
60 ℃
++++
Mercury
-
60 ℃
++++
Nitric acid
10%
20 ℃
+
Hydrochloric acid
10%
20 ℃
+
Sulfur dioxide
low
60 ℃
++++
Sulfuric acid
25%
20 ℃
++
10%
20 ℃
+++
Hydrogen sulfide
low
60 ℃
++++
Carbon tetrachloride
-
60 ℃
++++
Toluene
-
20 ℃
++++
-
60 ℃
+++
Detergent
high
60 ℃
++++
Plasticizer
-
60 ℃
++++
Explanation of the rating
++++
Resistant
+++
Practically resistant
++
Conditionally resistant
+
Less resistant
Not resistant
w.
Water solution
c. s.
Cold saturated