System Manual
Table Of Contents
- SIMATIC RF200
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Planning the RF200 system
4.4 Chemical resistance of the reader and transponders
SIMATIC RF200
114 System Manual, 03/2019, J31069-D0227-U001-A11-7619
Substance
Test conditions
Rating
Concentration [%]
Temperature [°C]
Chlorobenzene
-
20 ℃
++++
Chlorides (ammonium–, Na– among
others)
- 60 ℃ ++++
Chloroform
-
20 ℃
○
Chlorophyll
-
20 ℃
++++
Chlorosulfuric acid
100%
20 ℃
○
Chlorine water (saturated solution)
-
20 ℃
++
Chromates (K–, Na– among others)
Up to 50 %
40 ℃
++++
Chromic acid
Up to 30 %
20 ℃
○
Chromosulfuric acid
-
20 ℃
○
Citric acid
-
20 ℃
++++
Cyanamide
-
20 ℃
++++
Cyanides (K–, Na– among others)
-
60 ℃
++++
Dextrin, w.
-
60 ℃
++++
Diethyl ether
-
20 ℃
++++
Diethylene glycol
-
60 ℃
++++
Dimethyl ether
-
20 ℃
++++
Dioxane
-
20 ℃
○
Developer
-
40 ℃
++++
Acetic acid
100%
20 ℃
++
Ethanol
-
60 ℃
++++
Fixing bath
-
40 ℃
++++
Fluorides (ammonium–, K–, Na–
among others)
- 40 ℃ ++++
Hydrofluoric acid
Up to 40 %
20 ℃
++++
Formaldehyde
50%
20 ℃
++++
Formamide
100%
20 ℃
++++
Gluconic acid
-
20 ℃
++++
Glycerine
-
60 ℃
++++
Glycol
-
60 ℃
++++
Urine
-
20 ℃
++++
Uric acid
-
20 ℃
++++
Hydroxides (ammonium...)
10%
20 ℃
++++
Hydroxides (Na–, K–)
40%
20 ℃
++++
Hydroxides (alkaline earth metal)
-
60 ℃
++++
Hypochlorites (K–, Na– among others)
-
60 ℃
++++
Iodides (K–, Na– among others)
-
60 ℃
++++
Silicic acid
-
60 ℃
++++
Cresol
Up to 90 %
20 ℃
○
Methanol
100%
40 ℃
++++
Methylene chloride
-
20 ℃
○