System Manual

Table Of Contents
Planning the RF200 system
4.4 Chemical resistance of the reader and transponders
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
115
Substance
Test conditions
Rating
Concentration [%]
Temperature [°C]
Lactic acid
100%
20 ℃
++
Mineral oils
-
40 ℃
++++
Nitrates (ammonium..., K among
others)
- 60 ℃ ++++
Nitroglycerin
-
20 ℃
Oxalic acid
-
20 ℃
++++
Phenol
1%
20 ℃
++++
Phosphates (ammonium..., Naamong
others)
60 ℃ ++++
Phosphoric acid
50%
60 ℃
++++
85%
20 ℃
++++
Propanol
-
20 ℃
++++
Nitric acid
25%
20 ℃
Hydrochloric acid
10%
20 ℃
Brine
-
60 ℃
Sulfur dioxide
100%
20 ℃
++
Carbon disulfide
100%
20 ℃
Sulfuric acid
40%
20 ℃
Sulfurous acid
-
20 ℃
++
Soap solution
-
60 ℃
++++
Sulphates (ammonium..., Naamong
others)
- 60 ℃ ++++
Sulfites (ammonium..., Naamong
others)
- 60 ℃
Tar, aroma-free
-
60 ℃
++++
Turpentine
-
20 ℃
++++
Trichloroethylene
-
20 ℃
Hydrogen peroxide
30%
20 ℃
++++
Tartaric acid
-
20 ℃
++++
Explanation of the rating
++++
Resistant
+++
Practically resistant
++
Conditionally resistant
+
Less resistant
Not resistant