Planning the RF200 system
4.4 Chemical resistance of the reader and transponders
SIMATIC RF200
118 System Manual, 03/2019, J31069-D0227-U001-A11-7619
4.4.2.5 Polyphenylene sulfide (PPS)
The data memory has special chemical resistance to solutions up to a temperature of 200
°C. A reduction in the mechanical properties has been observed in aqueous solutions of
hydrochloric acid (HCl) and nitric acid (HNO3) at 80 °C. The plastic housings are resistant to
all types of fuel including methanol.
Table 4- 62 Chemical resistance - polyphenylene sulfide (PPS)
Substance
Test conditions
Rating
Concentration [%]
Temperature [°C]
Acetone
-
55 ℃
++++
n-Butanol (butyl alcohol)
-
80 ℃
++++
Butanone-2 (methyl ethyl ketone)
-
60 ℃
++++
n-Butyl acetate
-
80 ℃
++++
Brake fluid
-
80 ℃
++++
Calcium chloride (saturated)
-
80 ℃
++++
Diesel fuel
-
80 ℃
++++
Diethyl ether
-
23 ℃
++++
Frigen 113
-
23 ℃
++++
Anti-freeze
-
120 ℃
++++
Kerosene
-
60 ℃
++++
Methanol
-
60 ℃
++++
Engine oil
-
80 ℃
++++
Sodium chloride (saturated)
-
80 ℃
++++
Sodium hydroxide
30%
80 ℃
++++
Sodium hypochlorite
(30 or 180 days)
5%
80 ℃
++
5% 80 ℃ -
Sodium hydroxide solution
30%
90 ℃
++++
Nitric acid
10%
23 ℃
++++
Hydrochloric acid
10%
80 ℃
-
Sulfuric acid
10%
23 ℃
++++
10%
80 ℃
++
30%
23 ℃
++++
Tested fuels
-
80 ℃
++++
FAM testing fluid
acc. to DIN 51 604-A
Toluene
- 80 ℃ ++
1, 1, 1-Trichloroethane
Xylene
- 80 ℃ ++++
Zinc chloride (saturated)
-
80 ℃
++
-
75 ℃
++++