System Manual
Table Of Contents
- SIMATIC RF200
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Readers
5.2 SIMATIC RF210M
SIMATIC RF200
132 System Manual, 03/2019, J31069-D0227-U001-A11-7619
6GT2823-0AA00
Permitted ambient conditions
Ambient temperature
• During operation • -20 … +50 °C
• During transportation and storage • -25 … +60 °C
Degree of protection to EN 60529
IP54
Shock-resistant acc. to EN 60721-3-7, Class 7
M2
500 m/s
2
Vibration-resistant acc. to EN 60721-3-7, Class 7
M2
200 m/s
2
Design, dimensions and weight
Dimensions
• Reader with handle (L x W x H) • 195 x 26 x 140 mm
• Reader without handle (L x W x H) • 195 x 26 x 46 mm
• Spiral connecting cable (L)
• 2 m
maximum working length 3.5 m
Weight
460 g
Type of mounting
Bracket for for hanging up
Cable length for RS-422 interface, maximum
1000 m
LED display design 3-color LED
(operating voltage, presence, error)
5.2.7 Approvals
FCC information
Siemens SIMATIC RF210R (MLFB 6GT2821-1AC10) FCC ID NXW-RF210R
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.