Safety distances
CAUTION
Safety distance between reader/antenna and persons
Note that for permanent exposure, the following safety distances must be adhered to:
RF210R: ≥ 25 mm
RF220R: ≥ 50 mm
RF240R: ≥ 100 mm
RF250R + ANT 1: ≥ 120 mm
RF250R + ANT 3 or ANT 30: ≥ 50 mm
RF250R + ANT 3S or ANT 12: ≥ 25 mm
RF250R + ANT 18: ≥ 40 mm
RF260R: ≥ 120 mm
RF280R: ≥ 250 mm
RF285R + ANT D1: ≥ 250 mm
RF285R + ANT D5: ≥ 400 mm
RF285R + ANT D6: ≥ 450 mm
RF290R + ANT D1: ≥ 250 mm (max. 2 W permissible)
RF290R + ANT D5: ≥ 450 mm
RF290R + ANT D6: ≥ 600 mm
RF290R + ANT D10: 600 mm
Note
Safety distance with pacemakers
An increased safety distance between reader/antenna and persons with pacemakers is not
necessary.