System Manual

Table Of Contents
Readers
5.8 SIMATIC RF285R
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
173
5.8.6 Technical specifications
Table 5- 19 Technical specifications of the RF285R reader
6GT2821-7AC12
Product type designation
SIMATIC RF285R
Radio frequencies
Operating frequency, rated value
13.56 MHz
Electrical data
Maximum range
550 mm
Maximum data transmission speed
Reader ↔ transponder
ISO transponder
Read Approx. 1500 bytes/s
Write Approx. 1500 bytes/s
Typical transmission time for user data per byte
for write access 0.6 ms
for read access 0.6 ms
Multitag capability
Yes
Transmission speed
19.2, 57.6, 115.2 kBd
Read/write distances of the reader
See section "Field data (Page 39)"
MTBF (Mean Time Between Failures)
18 years
Interfaces
Electrical connector design
M12, 8-pin
Standard for interfaces for communication
RS232
Antenna external
ANT D1, D5 or D6 can be connected
Antenna connection
TNC socket
Mechanical specifications
Housing
Material Aluminum die-casting
Color Silver/anthracite
Recommended distance to metal
0 mm
Supply voltage, current consumption, power loss
Supply voltage
24 V DC (± 10%)
Typical current consumption
200 mA (at 24 V and 2 W transmit power)