System Manual
Table Of Contents
- SIMATIC RF200
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Readers
5.9 SIMATIC RF290R
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
189
5.9.8 Note on the use of the RF290R as a replacement for SLG D10 / SLG D10S
The RF290R reader is the successor to the MOBY D readers SLG D10 / SLG D10S
rounding off the RF200 family; it is operated with external antennas. The following features
distinguish the RF290R from the SLG models:
Table 5- 27 Differences between the RF290R readers and SLG D10 / SLG D10S
Properties SLG D10/SLG D10S
Properties RF290R
Two devices with different interfaces RS-232/RS-422 interface and PC/CM functionali-
ty in one device
M 12, 4-pin male connector for the power supply
9-pin D-sub male connector for connection to the
various communications modules
M12, 8-pin male connector for the power supply
and for direct connection to the various commu-
nications modules
1)
no digital I/O M12, 4-pin female connector for digital I/O (can
only be used in PC mode)
no operating display via LEDs
operating display by four LEDs
Maximum transmit power of 10 W
Maximum transmit power of 5 W
One securing option
Different securing options
Standard protocol in ISO host mode (in PC
mode)
Advanced protocol in ISO host mode (in PC
mode)
2)
Amplitude Shift Keying (ASK) and Frequency
Shift Keying (FSK) modes possible
Amplitude Shift Keying (ASK) mode possible
Support of "ICode1" and "TagIt" and ISO 15693-
compatible transponders
Support of ISO 15693-compatible transponders
The total memory for "repeat_command" is lim-
ited to 32 kB
The total memory for "repeat_command" is lim-
ited to 16 kB
1)
The RF290R reader connectors are compatible with the SLG D10 if a Y connecting cable is used
(6GT2891-4KH50, 6GT2891-4KH50-0AX0).
2)
In ISO host mode (in PC mode), a program adaptation is necessary