System Manual
Table Of Contents
- SIMATIC RF200
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety notes
- 3 System overview
- 4 Planning the RF200 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF200 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Permissible directions of motion of the transponder
- 4.1.6 Operation in static and dynamic mode
- 4.1.7 Dwell time of the transponder
- 4.1.8 Communication between communication module, reader and transponder
- 4.2 Field data of transponders and readers
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the reader and transponders
- 4.5 Further information
- 4.1 Fundamentals of application planning
- 5 Readers
- 5.1 SIMATIC RF210R
- 5.2 SIMATIC RF210M
- 5.3 SIMATIC RF220R
- 5.4 SIMATIC RF240R
- 5.5 SIMATIC RF250R
- 5.6 SIMATIC RF260R
- 5.7 SIMATIC RF280R
- 5.8 SIMATIC RF285R
- 5.9 SIMATIC RF290R
- 6 Antennas
- 7 Transponder
- 7.1 Memory configuration of ISO the transponders
- 7.2 MDS D100
- 7.3 MDS D117
- 7.4 MDS D124
- 7.5 MDS D126
- 7.6 MDS D127
- 7.7 MDS D139
- 7.8 MDS D160
- 7.9 MDS D165
- 7.10 MDS D200
- 7.11 MDS D261
- 7.12 MDS D324
- 7.13 MDS D339
- 7.14 MDS D400
- 7.15 MDS D421
- 7.16 MDS D422
- 7.17 MDS D423
- 7.18 MDS D424
- 7.19 MDS D425
- 7.20 MDS D426
- 7.21 MDS D428
- 7.22 MDS D460
- 7.23 MDS D521
- 7.24 MDS D522
- 7.25 MDS D522 special variant
- 7.26 MDS D524
- 7.27 MDS D525
- 7.28 MDS D526
- 7.29 MDS D528
- 7.30 MDS D560
- 8 System integration
- 9 System diagnostics
- A Appendix
Antennas
6.6 ANT 12 (stainless steel variant)
SIMATIC RF200
222 System Manual, 03/2019, J31069-D0227-U001-A11-7619
6GT2398-1DC00
1)
6GT2398-1DC10
Design, dimensions and weight
Dimensions (∅ x L)
12 x 40 mm
Thread (∅ x thread x L)
M12 x 1 x 30 mm
Weight without cable/with cable
15 g / 180 g
Type of mounting
2x stainless steel nuts M12 x 1
1)
Investigated by UL
The products 6GT2398-1DC10 and 6GT2398-1DC00 are identical in structure and only differ in
the antenna connecting cable included in the scope of delivery.
2)
The supply source and ext. circuits intended to be connected to this device shall be galv. separat-
ed from mains supply or hazardous live voltage by reinforced or double insulation and meet the
requirements of SELV/PELV circuit of UL/IEC61010-2-201 and clause 9.4 Limited energy circuit of
UL/IEC 61010-1 or Class 2 of NEC or LPS of UL/IEC 60950”.
3)
Warning: The values for shock and vibration are maximum values and must not be applied contin-
uously.
6.6.8 Dimension drawing
①
The antenna connector may only be tightened by hand.
②
The cable must be secured in front of/behind the support sleeve so that no bending strain can
be transferred to the antenna connector.
Figure 6-29 Dimension drawing ANT 12 (stainless steel variant)
All dimensions in mm.