Antennas
6.7 ANT 18
SIMATIC RF200
System Manual, 03/2019, J31069-D0227-U001-A11-7619
227
6GT2398-1CA00
6GT2398-1CA10
Permitted ambient conditions
Ambient temperature
During operation -20 ... +70 °C
During transportation and storage -40 ... +85 °C
Degree of protection to EN 60529
IP67 (front)
Shock-resistant according to EN 60721-3-7 Class
7 M2
1)
500 m/s
2
Vibration-resistant according to EN 60721-3-7
Class 7 M2
1)
200 m/s
2
Design, dimensions and weight
Dimensions (∅ x thread x L)
M18 x 1 x 55 mm
Weight
130 g
Type of mounting
2x plastic nuts M18 x 1
Cable length
3 m or 0.6 m
1)
Warning: The values for shock and vibration are maximum values and must not be applied contin-
uously.
6.7.7 Dimension drawing
Figure 6-34 Dimension drawing ANT 18 (all values in mm)